Literature DB >> 20800975

Anatomic outcome of percutaneous release among patients with trigger finger.

Henry Calleja1, Antonio Tanchuling, David Alagar, Carolina Tapia, Anna Macalalad.   

Abstract

PURPOSE: To investigate the adequacy and safety of percutaneous trigger finger release on symptomatic patients.
METHODS: Two orthopedic non-hand surgeons performed percutaneous A1 pulley release on the thumb, index, middle, and ring fingers with the use of a 19-gauge needle in 25 fingers of 24 patients. Open inspection was then performed to determine the extent of release and any injury to the surrounding anatomic structures.
RESULTS: Triggering was eliminated in all fingers. Of the 25 A1 pulleys, 19 were partially released; only 6 were completely released. Noted injury included only superficial abrasions in 15 tendons. None of the patients had injury to the digital artery or nerve.
CONCLUSIONS: In the percutaneous release of trigger fingers, complete anatomic release of the A1 pulley is not always adequately achieved, even though clinically patients experience relief of triggering. It is a safe procedure for the thumb, index, middle, and ring fingers as long as the recommended technique is observed.
Copyright © 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20800975     DOI: 10.1016/j.jhsa.2010.06.006

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  2 in total

1.  A Cadaveric Study of the Thread Trigger Finger Release: The First Annular Pulley Transection Through Thread Transecting Technique.

Authors:  Danqing Guo; Danzhu Guo; Joseph Guo; Logan C McCool; Brionn Tonkin
Journal:  Hand (N Y)       Date:  2017-03-13

2.  Treatment of paediatric trigger finger: a systematic review and treatment algorithm.

Authors:  M E Womack; J C Ryan; V Shillingford-Cole; S Speicher; G D Hogue
Journal:  J Child Orthop       Date:  2018-06-01       Impact factor: 1.548