Direct observation of the human microcirculation during cardiopulmonary bypass: effects of pulsatile perfusion.

Paul W G Elbers1, Jeroen Wijbenga, Frank Solinger, Aladdin Yilmaz, Mat van Iterson, Eric P A van Dongen, Can Ince.   

Abstract

OBJECTIVES: Possible benefits of pulsatile perfusion during cardiopulmonary bypass often are attributed to enhanced microvascular flow. However, there is no evidence to support this in humans. Therefore, the authors assessed whether pulsatile perfusion alters human microvascular flow.
DESIGN: A prospective, randomized observational crossover study.
SETTING: A tertiary cardiothoracic surgery referral center. PARTICIPANTS: Sixteen patients undergoing routine cardiopulmonary bypass for cardiac surgery.
INTERVENTIONS: All patients underwent both pulsatile and nonpulsatile perfusion in random order.
MEASUREMENTS AND MAIN RESULTS: The authors used sidestream dark-field imaging to record video clips of the sublingual human microcirculation. Perfusion was started either in the pulsatile (n = 8) or the nonpulsatile mode. After 10 minutes, microvascular recordings were made. The perfusion mode was then switched, and after 10 minutes, new microvascular recordings were taken. The authors quantified pulsatile perfusion-generated surplus hemodynamic energy by calculating pulse pressure and energy-equivalent pressure. Microvascular analysis included determination of the perfused vessel density (mean ± standard deviation). This did not differ between nonpulsatile and pulsatile perfusion (6.65 ± 1.39 v 6.83 ± 1.23 mm(-1), p = 0.58, and 2.16 ± 0.64 v 1.96 ± 0.48 mm(-1), p = 0.20 for small and large microvessels, respectively, cutoff diameter = 20 μm). Pulse pressure and energy-equivalent pressure was higher during pulsatile perfusion. However, there was no correlation between the difference in energy-equivalent pressure or pulse pressure and perfused vessel density (r = -0.43, p = 0.13, and r = -0.09, p = 0.76, respectively).
CONCLUSION: Pulsatile perfusion does not alter human microvascular perfusion using standard equipment in routine cardiac surgery. Changes in pulse pressure or energy-equivalent pressure bear no obvious relationship with microcirculatory parameters.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20800509     DOI: 10.1053/j.jvca.2010.06.014

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  3 in total

1.  Microcirculatory Changes in Pediatric Patients During Congenital Heart Defect Corrective Surgery.

Authors:  Rafael González Cortés; Javier Urbano Villaescusa; María J Solana García; Jorge López González; Sarah N Fernández Lafever; Blanca Ramírez Gómez; José R Fuentes Moran; Irene Hidalgo García; Ana Peleteiro Pensado; Ramón Pérez-Caballero Martínez; Carlos A Pardo Prado; Alejandro Rodríguez Ogando; María López Blazquez; Jesús López-Herce Cid
Journal:  J Cardiovasc Transl Res       Date:  2021-05-04       Impact factor: 4.132

Review 2.  Prediction and Prevention of Acute Kidney Injury after Cardiac Surgery.

Authors:  Su Rin Shin; Won Ho Kim; Dong Joon Kim; Il-Woo Shin; Ju-Tae Sohn
Journal:  Biomed Res Int       Date:  2016-06-23       Impact factor: 3.411

3.  Postoperative microcirculatory perfusion and endothelial glycocalyx shedding following cardiac surgery with cardiopulmonary bypass.

Authors:  N A M Dekker; D Veerhoek; N J Koning; A L I van Leeuwen; P W G Elbers; C E van den Brom; A B A Vonk; C Boer
Journal:  Anaesthesia       Date:  2019-01-27       Impact factor: 6.955

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.