Literature DB >> 20800181

An increase in cellular size variance contributes to the increase in ultrasound backscatter during cell death.

Roxana M Vlad1, Ratan K Saha, Nehad M Alajez, Shawn Ranieri, Gregory J Czarnota, Michael C Kolios.   

Abstract

This study aims to explain the contribution of changes in cellular size variance (CSV) to increases in ultrasound-integrated backscatter (UIB) measured from cell samples undergoing cell death. A Monte Carlo algorithm was used to compare simulations of 2D distributions of cells, uniform (CSV = 0) versus heterogeneous (CSV > 0) and the same mean cellular size (M ). UIB increased in arrangements with heterogeneous cellular sizes from 3.6dB (M = 20 mum, CSV = 0 microm/CSV = 18 microm) to 5.6 dB (M =10 microm, CSV = 0 microm/CSV = 8 microm). Experimentally, UIB (10 to 30 MHz) was measured from cell samples of four tumor cell lines viable and undergoing cell death after radiotherapy and chemotherapy treatment. An increase of 3.8-7.5 dB (p < 0.001) in UIB was measured from three cell lines. No increase in UIB was measured from one cell line. An increase in CSV was found for all cell samples after cell death. The results suggest that an increase in CSV could have a significant contribution to the increases measured in UIB after cell death in cell samples exposed to anticancer therapies.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20800181     DOI: 10.1016/j.ultrasmedbio.2010.05.025

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  9 in total

1.  Ultrasonic backscatter coefficient quantitative estimates from high-concentration Chinese Hamster Ovary cell pellet biophantoms.

Authors:  Aiguo Han; Rami Abuhabsah; James P Blue; Sandhya Sarwate; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2011-12       Impact factor: 1.840

2.  A Method for Stereological Determination of the Structure Function From Histological Sections of Isotropic Scattering Media.

Authors:  Aiguo Han
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-06       Impact factor: 2.725

3.  Structure function for high-concentration biophantoms of polydisperse scatterer sizes.

Authors:  Aiguo Han; William O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-02       Impact factor: 2.725

4.  Assessment of accuracy of the structure-factor-size-estimator method in determining red blood cell aggregate size from ultrasound spectral backscatter coefficient.

Authors:  Ratan K Saha; Emilie Franceschini; Guy Cloutier
Journal:  J Acoust Soc Am       Date:  2011-04       Impact factor: 1.840

5.  Analysis of Two Quantitative Ultrasound Approaches.

Authors:  Pauline Muleki-Seya; Aiguo Han; Michael P Andre; John W Erdman; William D O'Brien
Journal:  Ultrason Imaging       Date:  2017-09-25       Impact factor: 1.578

6.  Ultrasound Scattering From Cell-Pellet Biophantoms and Ex Vivo Tumors Provides Insight Into the Cellular Structure Involved in Scattering.

Authors:  Pauline Muleki-Seya; William D O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-01-27       Impact factor: 2.725

7.  Three-dimensional quantitative ultrasound for detecting lymph node metastases.

Authors:  Emi Saegusa-Beecroft; Junji Machi; Jonathan Mamou; Masaki Hata; Alain Coron; Eugene T Yanagihara; Tadashi Yamaguchi; Michael L Oelze; Pascal Laugier; Ernest J Feleppa
Journal:  J Surg Res       Date:  2013-01-08       Impact factor: 2.192

8.  Structure Function Estimated From Histological Tissue Sections.

Authors:  Aiguo Han; William D O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-03-25       Impact factor: 2.725

9.  Ultrasonic spectrum analysis for in vivo characterization of tumor microstructural changes in the evaluation of tumor response to chemotherapy using diagnostic ultrasound.

Authors:  Chun-yi Lin; Long-hui Cao; Jian-wei Wang; Wei Zheng; Yao Chen; Zi-zhen Feng; An-hua Li; Jian-hua Zhou
Journal:  BMC Cancer       Date:  2013-06-21       Impact factor: 4.430

  9 in total