Literature DB >> 20798785

A DATA-DRIVEN APPROACH TO PRIOR EXTRACTION FOR SEGMENTATION OF LEFT VENTRICLE IN CARDIAC MR IMAGES.

Xiao Jia1, Chao Li, Ying Sun, Ashraf A Kassim, Yijen L Wu, T Kevin Hitchens, Chien Ho.   

Abstract

In this paper, we propose a data-driven approach that extracts prior information for segmentation of the left ventricle in cardiac MR images of transplanted rat hearts. In our approach, probabilistic priors are generated from prominent features, i.e., corner points and scale-invariant edges, for both endo-and epi-cardium segmentation. We adopt a level set formulation that integrates probabilistic priors with intensity, texture, and edge information for segmentation. Our experimental results show that with minimal user input, representative priors are correctly extracted from the data itself, and the proposed method is effective and robust for segmentation of the left ventricle myocardium even in images with very low contrast. More importantly, it avoids inter- and intra- observer variations and makes accurate quantitative analysis of low-quality cardiac MR images possible.

Entities:  

Year:  2009        PMID: 20798785      PMCID: PMC2927839          DOI: 10.1109/ISBI.2009.5193181

Source DB:  PubMed          Journal:  Proc IEEE Int Symp Biomed Imaging        ISSN: 1945-7928


  5 in total

1.  MRI investigations of graft rejection following organ transplantation using rodent models.

Authors:  Yi-Jen L Wu; Kazuya Sato; Qing Ye; Chien Ho
Journal:  Methods Enzymol       Date:  2004       Impact factor: 1.600

2.  STACS: new active contour scheme for cardiac MR image segmentation.

Authors:  Chamchai Pluempitiwiriyawej; José M F Moura; Yi-Jen Lin Wu; Chien Ho
Journal:  IEEE Trans Med Imaging       Date:  2005-05       Impact factor: 10.048

3.  Semiautomated segmentation of myocardial contours for fast strain analysis in cine displacement-encoded MRI.

Authors:  Ting Chen; James Babb; Peter Kellman; Leon Axel; Daniel Kim
Journal:  IEEE Trans Med Imaging       Date:  2008-08       Impact factor: 10.048

4.  Intensity correction in surface-coil MR imaging.

Authors:  L Axel; J Costantini; J Listerud
Journal:  AJR Am J Roentgenol       Date:  1987-02       Impact factor: 3.959

5.  Novel MRI method to detect altered left ventricular ejection and filling patterns in rodent models of disease.

Authors:  Daniel J Stuckey; Carolyn A Carr; Damian J Tyler; Ellen Aasum; Kieran Clarke
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.