Literature DB >> 20740533

Liquid chromatography/tandem mass spectrometry sensitivity enhancement via online sample dilution and trapping: applications in microdosing and dried blood spot (DBS) bioanalysis.

Fumin Li1, John P Zulkoski, Jie Ding, Wes Brown, Tom Addison.   

Abstract

A simple online sample dilution, enrichment, and cleanup technique was developed for sensitive microdosing and dried blood spot (DBS) liquid chromatography/tandem mass spectrometric (LC/MS/MS) bioanalysis. Samples are diluted online with water and enriched in a trap column which is subsequently switched inline with the analytical column. Excellent lansoprazole (in acetonitrile) peak shape is maintained even with an 80-microL injection. In comparison, similar chromatographic peaks were observed only when a small volume of the same solution, i.e., 1 microL, was injected on a regular high-performance liquid chromatography (HPLC) system, where an injection of 5 microL resulted in severe peak fronting. A substantial enhancement in sensitivity is realized in the trapping mode using large injection volumes. The trap column is washed at the beginning and at the end of each injection with aqueous and organic solvent respectively to remove matrix components. This ultimately leads to reduction of matrix effects and mass spectrometer noise, thus facilitating the utilization of protein precipitation as the sample preparation for plasma samples. A lower limit of quantitation (LLOQ) of 0.5 pg/mL was demonstrated for lansoprazole in human plasma with a signal-to-noise (S/N) ratio of 13 using a 100 microL injection. Excellent intra-day precision and accuracy were established for lansoprazole in human plasma with good linearity (R(2) > 0.999) from 0.5 to 500 pg/mL. This level of LLOQ makes LC/MS/MS a practical alternative for microdosing bioanalysis, where the dose is typically 100 times lower than the therapeutic dose. The same technique was applied to quantitate lansoprazole in human whole blood employing DBS technology. With a single 3-mm punch, i.e. approximately 2 microL of whole blood or approximately 1 microL plasma, a LLOQ of 0.1 ng/mL showed sufficient S/N ratio (40) for lansoprazole when 75 microL of extract was injected. In all, the online sample dilution, cleanup, and enrichment technique demonstrated the practical utility of LC/MS/MS in microdosing and DBS bioanalysis. Copyright 2010 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20740533     DOI: 10.1002/rcm.4670

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

Review 1.  Applications of Tandem Mass Spectrometry (MS/MS) in Protein Analysis for Biomedical Research.

Authors:  Anca-Narcisa Neagu; Madhuri Jayathirtha; Emma Baxter; Mary Donnelly; Brindusa Alina Petre; Costel C Darie
Journal:  Molecules       Date:  2022-04-08       Impact factor: 4.927

2.  Performance and storage integrity of dried blood spots for PCB, BFR and pesticide measurements.

Authors:  Stuart Batterman; Sergei Chernyak
Journal:  Sci Total Environ       Date:  2014-07-21       Impact factor: 7.963

3.  Optimizing oxytocin LC-MS/MS sensitivity by choosing the right column.

Authors:  Mariëtte T Ackermans
Journal:  Pract Lab Med       Date:  2021-09-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.