Detection of the insertion end point of cementless hip prostheses using the comparison between successive frequency response functions.

L C Pastrav1, S V N Jaecques, M Mulier, G Van Der Perre.   

Abstract

Vibration analysis is a non-destructive testing technique, which has a potential to assess the mechanical properties of the stem/femur system in total hip replacement (THR). Different methods based on vibration analysis have already been successfully used to determine bone mechanical properties, to monitor fracture healing, and to quantify the fixation of dental implants. This paper describes an in vitro study of the change in the frequency response function (FRF) of the hip stem/femur structure during implant insertion. At successive insertion stages, the FRF of the system was measured by impulse excitation on the prosthesis neck, in the range 0-5000 Hz. To quantify the difference between two successive FRF spectra, the Pearson's correlation coefficient and the cross correlation function were used. The stiffness of the implant/bone system varies during insertion, which results in a change in FRF, especially in the range of higher frequencies. If the FRF spectrum shifts to the right, then the stiffness of the implant/bone connection increases and, consequently, the stability of the implant increases as well. If the FRF does not change between two successive insertion stages, then the mechanical properties of the prosthesis-femur structure does not change; therefore, the stem-bone connection is stable and the insertion should stop to avoid intra-operative fractures. Based on the obtained results, a per-operative protocol based on FRF analysis can be designed to assess the stability of a cementless hip prosthesis, and to detect the insertion end point.

Entities:  

Year:  2008        PMID: 20740443

Source DB:  PubMed          Journal:  J Appl Biomater Biomech        ISSN: 1722-6899


  6 in total

1.  Finite element model of the impaction of a press-fitted acetabular cup.

Authors:  Adrien Michel; Vu-Hieu Nguyen; Romain Bosc; Romain Vayron; Philippe Hernigou; Salah Naili; Guillaume Haiat
Journal:  Med Biol Eng Comput       Date:  2016-08-04       Impact factor: 2.602

2.  Modal Analysis of the Ancillary During Femoral Stem Insertion: A Study on Bone Mimicking Phantoms.

Authors:  Anne-Sophie Poudrel; Giuseppe Rosi; Vu-Hieu Nguyen; Guillaume Haiat
Journal:  Ann Biomed Eng       Date:  2022-01-07       Impact factor: 3.934

3.  Development of an Instrument to Assess the Stability of Cementless Femoral Implants Using Vibration Analysis During Total Hip Arthroplasty.

Authors:  Steven Leuridan; Quentin Goossens; Leonard Cezar Pastrav; Michiel Mulier; Wim Desmet; Jos Vander Sloten; Kathleen Denis
Journal:  IEEE J Transl Eng Health Med       Date:  2021-11-15       Impact factor: 3.316

4.  Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study.

Authors:  Adrien Michel; Romain Bosc; Jean-Paul Meningaud; Philippe Hernigou; Guillaume Haiat
Journal:  PLoS One       Date:  2016-11-28       Impact factor: 3.240

5.  Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors.

Authors:  Antoine Tijou; Giuseppe Rosi; Philippe Hernigou; Charles-Henri Flouzat-Lachaniette; Guillaume Haïat
Journal:  Sensors (Basel)       Date:  2017-12-27       Impact factor: 3.576

6.  In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses.

Authors:  Leonard C Pastrav; Siegfried Vn Jaecques; Ilse Jonkers; Georges Van der Perre; Michiel Mulier
Journal:  J Orthop Surg Res       Date:  2009-04-09       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.