Literature DB >> 2073982

Comparison of ABR amplitudes with TIPtrode and mastoid electrodes.

C D Bauch1, W O Olsen.   

Abstract

ABR evaluations were completed for 36 adults (18 males, 18 females) having normal hearing sensitivity and for 91 adult patients having various degrees of sensorineural hearing loss. Amplitudes of waves I and V were compared for ear canal (TIPtrode) electrode and mastoid electrode recordings. Interpeak intervals (I-III, III-V, and I-V) were determined and upper 95% confidence limits defined for normative data. In general, amplitude of wave I was larger when TIPtrodes were used. Wave V amplitude was nearly identical for the two electrodes. Wave I was identified more frequently for TIPtrode than for mastoid recordings of ABR waveforms for the sensorineural hearing loss subjects.

Entities:  

Mesh:

Year:  1990        PMID: 2073982     DOI: 10.1097/00003446-199012000-00010

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  7 in total

1.  Using concha electrodes to measure cochlear microphonic waveforms and auditory brainstem responses.

Authors:  Ming Zhang
Journal:  Trends Amplif       Date:  2010-12-03

Review 2.  Effectiveness of Auditory Measures for Detecting Hidden Hearing Loss and/or Cochlear Synaptopathy: A Systematic Review.

Authors:  Christi M Barbee; Jessica A James; Jin Hyung Park; Emily M Smith; Carole E Johnson; Shari Clifton; Jeffrey L Danhauer
Journal:  Semin Hear       Date:  2018-06-15

3.  Auditory Brainstem Response Wave I Amplitude Has Limited Clinical Utility in Diagnosing Tinnitus in Humans.

Authors:  Katie Turner; Omid Moshtaghi; Neil Saez; Matthew Richardson; Hamid Djalilian; Fan-Gang Zeng; Harrison Lin
Journal:  Brain Sci       Date:  2022-01-21

4.  Supra-threshold auditory brainstem response amplitudes in humans: Test-retest reliability, electrode montage and noise exposure.

Authors:  Garreth Prendergast; Wenhe Tu; Hannah Guest; Rebecca E Millman; Karolina Kluk; Samuel Couth; Kevin J Munro; Christopher J Plack
Journal:  Hear Res       Date:  2018-04-06       Impact factor: 3.208

5.  Techniques for Obtaining High-quality Recordings in Electrocochleography.

Authors:  Michael J Simpson; Skyler G Jennings; Robert H Margolis
Journal:  Front Syst Neurosci       Date:  2020-04-15

Review 6.  Comparison of auditory brainstem response peak measures using ear lobe, mastoid, and custom ear canal reference electrodes.

Authors:  Samuel R Atcherson; Timothy J Lim; Page C Moore; Carlos P Minaya
Journal:  Audiol Res       Date:  2012-01-10

7.  Simultaneous Extratympanic Electrocochleography and Auditory Brainstem Responses Revisited.

Authors:  Carlos Minaya; Samuel R Atcherson
Journal:  Audiol Res       Date:  2015-03-03
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.