Literature DB >> 20737465

Determination of free bilirubin and its binding capacity by HSA using a microfluidic chip-capillary electrophoresis device with a multi-segment circular-ferrofluid-driven micromixing injection.

Hui Sun1, Zhou Nie, Ying Sing Fung.   

Abstract

A PMMA microfluidic chip-CE device with a multi-segment circular-ferrofluid-driven micromixing injector has been developed for the determination of free bilirubin and its binding capacity by HSA at equilibrium. The design of the device and its fabrication by a low cost CO(2) laser are discussed for intended applications. Under optimized conditions, the total binding capacity of HSA for bilirubin was determined as 16.3±1.4 mg/l00 mL human serum (n=3) and residual binding capacity for bilirubin 9.8 mg/100 mL (n=3) in normal infants. To assess risk of hyperbilirubinemia, free bilirubin and residual binding capacity by HSA provide a better indicator than total bilirubin, as neonates with impaired bilirubin binding capacity could be detected. In addition, residual binding capacity provides an advanced indicator to predict the onset of hyperbilirubinemia before the appearance of free bilirubin. HSA down to 94 nL is used in each titration and a full assay of four titrations takes up 376 nL HSA, sufficient for newborns with HSA in microliter range. The device has shown capable to provide adequate margin of protection to detect an early rising level of bilirubin and impaired binding capacity prior to the onset of jaundice condition.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20737465     DOI: 10.1002/elps.200900749

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  5 in total

1.  Integrated microfluidic chip for rapid DNA digestion and time-resolved capillary electrophoresis analysis.

Authors:  Che-Hsin Lin; Yao-Nan Wang; Lung-Ming Fu
Journal:  Biomicrofluidics       Date:  2012-03-15       Impact factor: 2.800

2.  Paper-based device for the colorimetric assay of bilirubin based on in-situ formation of gold nanoparticles.

Authors:  Resmi P Edachana; Abishek Kumaresan; Vidhya Balasubramanian; Ramachandran Thiagarajan; Bipin G Nair; Satheesh Babu Thekkedath Gopalakrishnan
Journal:  Mikrochim Acta       Date:  2019-12-17       Impact factor: 5.833

3.  Fluorescent sensing of free bilirubin at nanomolar level using a Langmuir-Blodgett film of glucuronic acid-functionalized gold nanoclusters.

Authors:  Wenxiang Xiao; Jing Liu; Yinan Xiong; Yaoxin Li; Hua Li
Journal:  Anal Bioanal Chem       Date:  2021-09-18       Impact factor: 4.142

4.  Convenient quantification of methanol concentration detection utilizing an integrated microfluidic chip.

Authors:  Yao-Nan Wang; Ruey-Jen Yang; Wei-Jhong Ju; Ming-Chang Wu; Lung-Ming Fu
Journal:  Biomicrofluidics       Date:  2012-08-13       Impact factor: 2.800

5.  Experimental and numerical analysis of high-resolution injection technique for capillary electrophoresis microchip.

Authors:  Chin-Lung Chang; Jik-Chang Leong; Ting-Fu Hong; Yao-Nan Wang; Lung-Ming Fu
Journal:  Int J Mol Sci       Date:  2011-06-03       Impact factor: 5.923

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.