Abstract

OBJECTIVE: To analyze the safety, adequacy and accuracy of tru-cut biopsy and to evaluate factors potentially affecting adequacy.
METHODS: We analyzed retrospectively a group of patients who had undergone tru-cut biopsy for either primary suboptimally operable tumors, recurrence or suspected non-genital or secondary tumor. Tru-cut biopsy was performed either transvaginally or transabdominally, using an automatic biopsy gun with disposable needle and needle guide attached to the probe. The adequacy, i.e. obtaining a sample sufficient for identification of the origin of the tumor and performance of immunohistochemistry; accuracy, i.e. agreement between biopsy and final postoperative histology; and safety, as determined by complication rate, were assessed. Variables potentially influencing adequacy were analyzed using the orthogonal projections to latent structure method.
RESULTS: A total of 195 biopsies were performed on 190 patients. An adequate sample was obtained in 178 (91.3%) biopsies. The final histology was not in agreement with the result from tru-cut biopsy in two out of 118 patients who underwent subsequent surgery (accuracy 98.3%). There were complications in two cases out of the 195 biopsies performed (1.0%). Ascites, elevated CA 125, primary suboptimal operable tumor, serous epithelial ovarian cancer histology, carcinomatosis and vaginal approach were significant positive predictors for the achievement of an adequate sample, while recurrence as an indication, non-serous and non-ovarian histotypes and transabdominal approach were negative predictors.
CONCLUSION: Ultrasound-guided tru-cut biopsy is an efficient, minimally invasive, accurate and safe diagnostic method in the management of advanced, recurrent or atypical abdominal and pelvic tumors of probable non-genital origin, where unnecessary laparotomy or laparoscopy can be avoided. The adequacy of tru-cut biopsy is mainly influenced by indication group, histology, site of biopsy and approach. Our analysis can help in counseling the patient before the procedure and helps to explain the possible causes of failure of the procedure.
Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 20737454     DOI: 10.1002/uog.8803

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  12 in total

Review 1.  Ultrasound in gynecological cancer: is it time for re-evaluation of its uses?

Authors:  Daniela Fischerova; David Cibula
Journal:  Curr Oncol Rep       Date:  2015-06       Impact factor: 5.075

2.  Comparison of Tru-Cut Biopsy and Incisional Biopsy in Achieving Prompt Diagnosis of Maxillofacial Pathology.

Authors:  Parimal Ranchhod Kansagara; H R Shiva Kumar; Kirthi Kumar Rai; K R Chatura; Hetal Ashokkumar Bera
Journal:  J Maxillofac Oral Surg       Date:  2021-04-10

Review 3.  Ultrasound-Guided Trans-Uterine Cavity Core Needle Biopsy of Uterine Myometrial Tumors to Differentiate Sarcoma from a Benign Lesion-Description of the Method and Review of the Literature.

Authors:  Maciej Stukan; Piotr Rutkowski; Jeremy Smadja; Sylvie Bonvalot
Journal:  Diagnostics (Basel)       Date:  2022-05-29

Review 4.  Role of ultrasound in the detection of recurrent ovarian cancer: a review of the literature.

Authors:  Andrea Rosati; Salvatore Gueli Alletti; Vito Andrea Capozzi; Mariateresa Mirandola; Virginia Vargiu; Camilla Fedele; Stefano Uccella; Carmine Vascone
Journal:  Gland Surg       Date:  2020-08

5.  Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

Authors:  Hailing Wang; Fangxuan Li; Juntian Liu; Sheng Zhang
Journal:  Pediatr Surg Int       Date:  2013-11-05       Impact factor: 1.827

6.  Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

Authors:  Feng Mao; Yi Dong; Zhengbiao Ji; Jiaying Cao; Wen-Ping Wang
Journal:  Biomed Res Int       Date:  2017-01-04       Impact factor: 3.411

7.  Transvaginal Ultrasound-Guided Core Biopsy-Experiences in a Comprehensive Cancer Centre.

Authors:  Dániel Lengyel; Ildikó Vereczkey; Krisztina Kőhalmy; Kiarash Bahrehmand; Zoltán Novák
Journal:  Cancers (Basel)       Date:  2021-05-25       Impact factor: 6.639

8.  Trucut Biopsy vs FNAC of Pelvic Tumors-Who Wins the Match?

Authors:  Asaranti Kar; Bharat Satapathy; Kaumudee Pattnaik; Prafulla K Dash
Journal:  J Cytol       Date:  2018 Jul-Sep       Impact factor: 1.000

9.  Extremely Late Recurrence of Ovarian Carcinoma Diagnosed by an Endoscopic Ultrasound-guided Fine-needle Biopsy.

Authors:  Mitsuru Chiba; Takashi Goto; Wataru Sato; Tomomi Shibuya; Kenichi Takahashi; Shinichiro Minami; Hisanori Matsuzawa; Yuki Sato; Katsunori Iijima
Journal:  Intern Med       Date:  2020-09-12       Impact factor: 1.271

Review 10.  The Role of Ultrasound Guided Sampling Procedures in the Diagnosis of Pelvic Masses: A Narrative Review of the Literature.

Authors:  Francesca Arezzo; Vera Loizzi; Daniele La Forgia; Adam Abdulwakil Kawosha; Erica Silvestris; Viviana Cataldo; Claudio Lombardi; Gerardo Cazzato; Giuseppe Ingravallo; Leonardo Resta; Gennaro Cormio
Journal:  Diagnostics (Basel)       Date:  2021-11-26