Literature DB >> 20737349

Remediating office environments of spore-forming bacteria.

Luke Johnson1, Myron L Smith, Melissa Begin, Bruce Fraser, J David Miller.   

Abstract

This study examines decontamination processes that were developed on an emergency basis to eliminate Bacillus anthracis spores from deliberately contaminated buildings. The recommended steps include a survey with sampling, the removal of sensitive items, and HEPA vacuuming of all readily available surfaces, followed by biocide treatment and subsequent analyses for viable cells. There are several analytical challenges posed by this approach. These include the ability to discriminate the added strain from naturally occurring resident microbes, determining detection limits for anthrax spores in settled dusts, and detecting viable but nonculturable spores. There are also logistical issues relating to the various skill sets required from investigation to reconstruction. In the present study, a model office was constructed, and a strain of Bacillus pumilus was isolated from the carpet and reintroduced to the office in excess. The abundance of the B. pumilus strain was monitored in settled dust using a strain-specific, quantitative polymerase chain reaction (QPCR)-based detection method following repeated HEPA vacuum cleanings. The QPCR method had a limit of detection corresponding to < or = 10(2) colony forming units per gram of settled dust. QPCR results were compared with measures of dust recoveries and fungal glucan and endotoxin levels in the dust samples. The largest fraction (ca. 81%) of added spores was recovered during the first HEPA cleaning. Subsequent cleanings resulted in incrementally lower recoveries, with removal of 93% of the initial inoculum by the third HEPA vacuuming. HEPA vacuuming prior to removal of items such as office contents and furnishings would result in much less resuspension of dust and limiting the extent of contamination. This approach also ensures that residual contaminants are as low as can be reasonably achieved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20737349     DOI: 10.1080/15459624.2010.508951

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  3 in total

1.  Walker occupancy has an impact on changing airborne bacterial communities in an underground pedestrian space, as small-dust particles increased with raising both temperature and humidity.

Authors:  Torahiko Okubo; Takako Osaki; Eriko Nozaki; Akira Uemura; Kouhei Sakai; Mizue Matushita; Junji Matsuo; Shinji Nakamura; Shigeru Kamiya; Hiroyuki Yamaguchi
Journal:  PLoS One       Date:  2017-09-18       Impact factor: 3.240

2.  Microbial inhibitors of the fungus Pseudogymnoascus destructans, the causal agent of white-nose syndrome in bats.

Authors:  Emma W Micalizzi; Jonathan N Mack; George P White; Tyler J Avis; Myron L Smith
Journal:  PLoS One       Date:  2017-06-20       Impact factor: 3.240

Review 3.  Considerations for estimating microbial environmental data concentrations collected from a field setting.

Authors:  Erin E Silvestri; Cynthia Yund; Sarah Taft; Charlena Yoder Bowling; Daniel Chappie; Kevin Garrahan; Eletha Brady-Roberts; Harry Stone; Tonya L Nichols
Journal:  J Expo Sci Environ Epidemiol       Date:  2016-02-17       Impact factor: 5.563

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.