Off-label use of drug-eluting versus bare metal stents: a lesion-specific systematic review of long-term outcomes.

Nirat Beohar1, Sheridan N Meyers, Ata Erdogan, Matthew E Harinstein, Karen Pieper, Stephanie Gagnon, Charles J Davidson.   

Abstract

OBJECTIVE: The purpose of this systematic review was to evaluate differences in lesion-specific outcomes with the "off-label" use of drug-eluting stents (DES) versus bare metal stents (BMS).
METHODS: MEDLINE, PubMed, the Cochrane databases, and other Web were searched for studies evaluating off-label use of DES and BMS with the same characteristics. Of 1,258 abstracts or manuscripts reviewed, 112 studies were included (total N = 23,438). Studies were excluded if patients received both types of stent or no stent; lesion type was unknown; lesion-specific outcomes for ≥6 months were unavailable; or <25 patients were enrolled.
RESULTS: Overall mortality at 6-12 months was approximately 3% for BMS and DES for off-label use. Increase in mortality was greater from 6-12 months to 2 years with BMS than with DES (3.3%-9.1%; 2.8%-4.1%); however, rates were similar at 3 years (BMS: 18.8%; DES:15.3%). Myocardial Infarction rates were similar for both types at 6-12 months (BMS: 6.5%; DES: 6.0%). Overall rates of stent thrombosis were 1.8% and 1.7% for BMS and DES, respectively. Similar or slightly lower rates of stent thrombosis were seen for most lesion types, except higher rates for small vessels for BMS (5.2%) and true bifurcation for DES (3.3%). Rates of target lesion revascularization (TLR) were 7.5% for BMS and 19.6% for DES at 6-12 months. At 2-years TLR remained lower than DES. When the combined group was compared to registry data alone, similar values were seen.
CONCLUSIONS: Rates of mortality, myocardial infarction (MI), and stent thrombosis were similar in patients receiving BMS or DES, while TLR rates were lower in DES patients. ©2010, Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20735712     DOI: 10.1111/j.1540-8183.2010.00588.x

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  1 in total

1.  Long-Term Predictors of Clinical Events after Off-Label Use of Drug-Eluting Stent beyond 1 Year.

Authors:  Kyeong Ho Yun; Jum Suk Ko; Sang Jae Rhee; Eun Mi Lee; Nam Jin Yoo; Nam-Ho Kim; Seok Kyu Oh; Jin-Won Jeong
Journal:  Korean Circ J       Date:  2013-03-31       Impact factor: 3.243