Literature DB >> 20735708

Using gas chromatography with ion mobility spectrometry to resolve explosive compounds in the presence of interferents.

Greg W Cook1, Peter T LaPuma, Gary L Hook, Brian A Eckenrode.   

Abstract

Ion mobility spectrometry (IMS) is a valued field detection technology because of its speed and high sensitivity, but IMS cannot easily resolve analytes of interest within mixtures. Coupling gas chromatography (GC) to IMS adds a separation capability to resolve complex matrices. A GC-IONSCAN® operated in IMS and GC⁄ IMS modes was evaluated with combinations of five explosives and four interferents. In 100 explosive/interferent combinations, IMS yielded 21 false positives while GC⁄ IMS substantially reduced the occurrence of false positives to one. In addition, the results indicate that through redesign or modification of the preconcentrator there would be significant advantages to using GC⁄ IMS, such as enhancement of the linear dynamic range (LDR) in some situations. By balancing sensitivity with LDR, GC⁄ IMS could prove to be a very advantageous tool when addressing real world complex mixture situations.

Year:  2010        PMID: 20735708     DOI: 10.1111/j.1556-4029.2010.01522.x

Source DB:  PubMed          Journal:  J Forensic Sci        ISSN: 0022-1198            Impact factor:   1.832


  4 in total

Review 1.  Coupling Front-End Separations, Ion Mobility Spectrometry, and Mass Spectrometry For Enhanced Multidimensional Biological and Environmental Analyses.

Authors:  Xueyun Zheng; Roza Wojcik; Xing Zhang; Yehia M Ibrahim; Kristin E Burnum-Johnson; Daniel J Orton; Matthew E Monroe; Ronald J Moore; Richard D Smith; Erin S Baker
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2017-02-23       Impact factor: 10.745

2.  Urinary Volatiles and Chemical Characterisation for the Non-Invasive Detection of Prostate and Bladder Cancers.

Authors:  Heena Tyagi; Emma Daulton; Ayman S Bannaga; Ramesh P Arasaradnam; James A Covington
Journal:  Biosensors (Basel)       Date:  2021-11-03

3.  Volatilomics-Based Microbiome Evaluation of Fermented Dairy by Prototypic Headspace-Gas Chromatography-High-Temperature Ion Mobility Spectrometry (HS-GC-HTIMS) and Non-Negative Matrix Factorization (NNMF).

Authors:  Charlotte C Capitain; Fatemeh Nejati; Martin Zischka; Markus Berzak; Stefan Junne; Peter Neubauer; Philipp Weller
Journal:  Metabolites       Date:  2022-03-28

4.  Detection of Adulteration in Canola Oil by Using GC-IMS and Chemometric Analysis.

Authors:  Tong Chen; Xinyu Chen; Daoli Lu; Bin Chen
Journal:  Int J Anal Chem       Date:  2018-09-23       Impact factor: 1.885

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.