Literature DB >> 20732805

Evaluation of doxorubicin toxicity on cardiomyocytes using a dual functional extracellular biochip.

Lidan Xiao1, Zhaoyin Hu, Wei Zhang, Chengxiong Wu, Hui Yu, Ping Wang.   

Abstract

Nowadays, cardiotoxicity induced by clinical drugs presents a high prevalence and has aroused great attention onto the effective and reliable drug evaluation before clinical treatment. Doxorubicin (Adriamycin), as a type of anthracycline chemotherapy agent for cancer treatment, was restricted in the clinical use because of its cardiotoxicity. In the present work, a dual functional biochip ExCell integrated with microelectrode arrays and interdigitated electrodes was designed to study the electrophysiological function and physical state of cardiomyocytes under the treatment of doxorubicin. Extracellular field potentials and cell-substrate impedance were measured to respectively express these two functions simultaneously in the same culture. The result detected by ExCell presented a portrait of cardiotoxicity induced by doxorubicin. The amplitude of extracellular field potentials decreased to 93%, 82% and 50% at 50 min treatment of doxorubicin with concentrations of 20 μM, 100 μM and 200 μM, respectively. Successively, beating rate decrease, beat-to-beat variation and Ca(2+) flux manifested severe abnormality. The cell-substrate impedance declined continuously in the depressing process of electrophysiological function and cell death was induced in high concentration treatment. All these result indicate that the biochip ExCell has the potential to be a fast-response and subtle tool for high-throughput drug evaluation assays.
Copyright © 2010. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20732805     DOI: 10.1016/j.bios.2010.07.093

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  A cell-based biosensor for real-time detection of cardiotoxicity using lensfree imaging.

Authors:  Sang Bok Kim; Hojae Bae; Jae Min Cha; Sang Jun Moon; Mehmet R Dokmeci; Donald M Cropek; Ali Khademhosseini
Journal:  Lab Chip       Date:  2011-04-11       Impact factor: 6.799

2.  Polymer-Based Functional Cantilevers Integrated with Interdigitated Electrode Arrays-A Novel Platform for Cardiac Sensing.

Authors:  Pooja P Kanade; Nomin-Erdene Oyunbaatar; Dong-Weon Lee
Journal:  Micromachines (Basel)       Date:  2020-04-24       Impact factor: 2.891

3.  High-Throughput Assessment of Drug Cardiac Safety Using a High-Speed Impedance Detection Technology-Based Heart-on-a-Chip.

Authors:  Xi Zhang; Tianxing Wang; Ping Wang; Ning Hu
Journal:  Micromachines (Basel)       Date:  2016-07-19       Impact factor: 2.891

4.  A biosensing system using a multiparameter nonlinear dynamic analysis of cardiomyocyte beating for drug-induced arrhythmia recognition.

Authors:  Hao Wang; Yue Wu; Quchao Zou; Wenjian Yang; Zhongyuan Xu; Hao Dong; Zhijing Zhu; Depeng Wang; Tianxing Wang; Ning Hu; Diming Zhang
Journal:  Microsyst Nanoeng       Date:  2022-05-09       Impact factor: 8.006

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.