Literature DB >> 20732803

Integrated optical biosensor for in-line monitoring of cell cultures.

Stéphanie Pasche1, Bernard Wenger, Réal Ischer, Marta Giazzon, Silvia Angeloni, Guy Voirin.   

Abstract

An analytical detection platform was developed to evaluate the induced toxicity in cell cultures exposed to foreign agents like growth factors or nanoparticles. Connecting a biosensing detection device to the cell culture flasks allows analyzing the composition of cell medium in real-time. The analysis relies on the quantification of inflammatory cytokines released by cells into the cell culture medium, by means of solid-phase immunoassays analyzed with the wavelength interrogated optical sensing (WIOS) instrument. A fluidic system for in situ measurements allows detecting cytokines in real-time, with a sensitivity of 1-100 ng/mL depending on the cytokine. In addition, integration of an in-line optical absorbance measurement unit, in combination with the standard AB cell proliferation assay, provides information on the cell viability in the culture. Fluidic connections between the cell culture flasks, the optical biosensor and the absorbance measurement unit simultaneously allow quantifying up to three cytokines (interleukin 8, interleukin 6 and the monocyte chemotactic protein), assessing cellular proliferation, and thus discriminating between naïve cells and cells exposed to foreign agents such as growth factors (tumor necrosis factor alpha) or nanoparticles. This analytical tool presents a high potential for assessing the cytotoxicity of nanoparticles and other chemicals in vitro.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20732803     DOI: 10.1016/j.bios.2010.07.087

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Magnetically-actuated, bead-enhanced silicon photonic immunosensor.

Authors:  Enrique Valera; Melinda S McClellan; Ryan C Bailey
Journal:  Anal Methods       Date:  2015-06-26       Impact factor: 2.896

2.  NCO-sP(EO-stat-PO) coatings on gold sensors--a QCM study of hemocompatibility.

Authors:  Stefan Sinn; Mirjam Eichler; Lothar Müller; Daniel Bünger; Jürgen Groll; Gerhard Ziemer; Frank Rupp; Hinnak Northoff; Jürgen Geis-Gerstorfer; Frank K Gehring; Hans P Wendel
Journal:  Sensors (Basel)       Date:  2011-05-13       Impact factor: 3.576

3.  Experimental Validation of the Sensitivity of Waveguide Grating Based Refractometric (Bio)sensors.

Authors:  Thomas E Gartmann; Florian Kehl
Journal:  Biosensors (Basel)       Date:  2015-04-13
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.