Literature DB >> 20730932

Tissue response to the components of a hydroxyapatite-coated composite femoral implant.

S A Hacking1, T Pauyo, L Lim, J G Legoux, M N Bureau.   

Abstract

Bone loss around femoral implants used for THA is a persistent clinical concern. It may be caused by stress shielding, generally attributed to a mismatch in stiffness between the implants and host bone. In this regard, a fatigue resistant, carbon fiber (CF) composite femoral implant with bone-matching stiffness has been developed. This study evaluated the tissue response to the three material components of this implant in normal and textured (blasted with 24 grit alumina) surfaces: the hydroxyapatite (HA) coating, the CF composite and the intermediate crystalline HA particulate composite layer to bond to the HA coating (blended). Sprague-Dawley rats underwent bilateral femoral implantation each receiving two rod-like implants. Bone apposition to the HA (37%) and textured Ti (41%) implants was not significantly different. Bone apposition to the untextured CF (14%) and blended (19%) implants and polished Ti (8%) implants was significantly lower. Bone apposition to the textured CF (9%) and blended (11%) implants was lower (but not statistically from the as received or untextured counterparts). Nearly all sections from femurs containing CF implants presented CF debris. There was no evidence of localized bone loss or any strong immune response associated with any of the implant materials. All materials were well tolerated with minimal inflammation despite the presence of particulate debris. The high degree of bone apposition to the HA-coated composite implants and the lack of short-term inflammation and adverse tissue response to the three material implant component support continued evaluation of this composite technology for use in THA. Published 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20730932     DOI: 10.1002/jbm.a.32758

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  6 in total

1.  Biologic Potential of Calcium Phosphate Biopowders Produced via Decomposition Combustion Synthesis.

Authors:  N Vollmer; K B King; R Ayers
Journal:  Ceram Int       Date:  2015-07-01       Impact factor: 4.527

2.  Debris of carbon-fibers originated from a CFRP (pEEK) wrist-plate triggered a destruent synovitis in human.

Authors:  Antonio Merolli; Lorenzo Rocchi; Marco De Spirito; Francesco Federico; Alessandro Morini; Luigi Mingarelli; Francesco Fanfani
Journal:  J Mater Sci Mater Med       Date:  2016-01-12       Impact factor: 3.896

3.  Experimental study on the biocompatibility of keratoprosthesis with improved titanium implant.

Authors:  Li Li; Hua Jiang; Li-Qiang Wang; Yi-Fei Huang
Journal:  Int J Ophthalmol       Date:  2018-11-18       Impact factor: 1.779

4.  Molecular plasma deposition: biologically inspired nanohydroxyapatite coatings on anodized nanotubular titanium for improving osteoblast density.

Authors:  Ganesan Balasundaram; Daniel M Storey; Thomas J Webster
Journal:  Int J Nanomedicine       Date:  2015-01-12

5.  Titanium Coating of the Boston Keratoprosthesis.

Authors:  Borja Salvador-Culla; Kyung Jae Jeong; Paraskevi Evi Kolovou; Homer H Chiang; James Chodosh; Claes H Dohlman; Daniel S Kohane
Journal:  Transl Vis Sci Technol       Date:  2016-04-28       Impact factor: 3.283

6.  In vitro and in vivo evaluations of the fully porous Ti6Al4V acetabular cups fabricated by a sintering technique.

Authors:  Ji Li; Wei Li; Zhongli Li; Yuxing Wang; Ruiling Li; Jiangping Tu; Gong Jin
Journal:  RSC Adv       Date:  2019-02-26       Impact factor: 4.036

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.