Literature DB >> 20729593

Electrochemical disinfection of secondary wastewater treatment plant (WWTP) effluent.

G Pérez1, P Gómez, R Ibañez, I Ortiz, A M Urtiaga.   

Abstract

In this work the electrochemical disinfection of the effluent of a secondary wastewater treatment plant is investigated. In the experimental work, performed on-site with real effluents of the WWTP located in Vuelta Ostrera (Cantabria, Spain), boron-doped diamond (BDD) electrodes were employed. The initial concentration of E. coli in the effluent of the WWTP varied in the range 1.3 x 10⁴-5.2 x 10⁵ cfu/mL. The influence of two operation variables on the kinetics of E. coli deactivation was investigated: i) The applied current density was varied in the range J=40-120 mA/cm², showing first order kinetics, and linear dependency of the apparent kinetic constant with the applied current density; and ii) the chloride concentration was varied in the range 60-1,050 mg/L, showing that increasing chloride content also enhanced the kinetics of the E. coli deactivation. The latter parameter is particularly important in coastal areas, as in the case of the present study. The formation of disinfection by-products (DBPs) was followed by measuring the content of trihalomethanes (THMs) that nevertheless was maintained below 100 μg/L, so it can be concluded that the formation of DBPs is not a disadvantage of electrochemical disinfection of secondary effluents of WWTP.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20729593     DOI: 10.2166/wst.2010.328

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  4 in total

1.  Inactivation, lysis and degradation by-products of Saccharomyces cerevisiae by electrooxidation using DSA.

Authors:  Lyliane F Trigueiro; Larissa M Silva; Luciana A B D Itto; Thiago M B F Oliveira; Artur J Motheo; Carlos A Martínez-Huitle; Janete J F Alves; Suely S L Castro
Journal:  Environ Sci Pollut Res Int       Date:  2016-08-05       Impact factor: 4.223

2.  Electrochemical disinfection and removal of ammonia nitrogen for the reclamation of wastewater treatment plant effluent.

Authors:  Jing Ding; Qing-Liang Zhao; Jun-Qiu Jiang; Liang-Liang Wei; Kun Wang; Yun-Shu Zhang; Wei-Zhu Hou; Hang Yu
Journal:  Environ Sci Pollut Res Int       Date:  2016-04-11       Impact factor: 4.223

3.  Electrochemical disinfection of toilet wastewater using wastewater electrolysis cell.

Authors:  Xiao Huang; Yan Qu; Clément A Cid; Cody Finke; Michael R Hoffmann; Keahying Lim; Sunny C Jiang
Journal:  Water Res       Date:  2016-01-21       Impact factor: 11.236

4.  Effect of microbial fuel cell operation time on the disinfection efficacy of electrochemically synthesised catholyte from urine.

Authors:  I Merino-Jimenez; O Obata; G Pasternak; I Gajda; J Greenman; I Ieropoulos
Journal:  Process Biochem       Date:  2021-02       Impact factor: 3.757

  4 in total