Literature DB >> 20729053

Fully integrated monolithic optoelectronic transducer for real-time protein and DNA detection: the NEMOSLAB approach.

Konstantinos Misiakos1, Panagiota S Petrou, Sotirios E Kakabakos, Drakoulis Yannoukakos, Harry Contopanagos, Thorsten Knoll, Thomas Velten, Marco DeFazio, Luigi Schiavo, Miriam Passamano, Dimitrios Stamou, George Nounesis.   

Abstract

The development and testing of a portable bioanalytical device which was capable for real-time monitoring of binding assays was demonstrated. The device was based on arrays of nine optoelectronic transducers monolithically integrated on silicon chips. The optocouplers consisted of nine silicon avalanche diodes self-aligned to nine silicon nitride waveguides all converging to a single silicon detector. The waveguides were biofunctionalized by appropriate recognition molecules. Integrated thick polymer microchannels provided the necessary fluidic functions to the chip. A single sided direct contact scheme through a board-to-board receptacle was developed and combined with a portable customized readout and control instrument. Real-time detection of deleterious mutations in BRCA1 gene related to predisposition to hereditary breast/ovarian cancer was performed with the instrument developed using PCR products. Detection was based on waveguided photons elimination through interaction with fluorescently labeled PCR products. Detection of single biomolecular binding events was also demonstrated using nanoparticles as labels. In addition, label-free monitoring of bioreactions in real time was achieved by exploiting wavelength filtering on photonic crystal engineered waveguides. The proposed miniaturized sensing device with proper packaging and accompanied by a portable instrument can find wide application as a platform for reliable and cost effective point-of-care diagnosis.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20729053     DOI: 10.1016/j.bios.2010.07.104

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Mycotoxin Biosensor Based on Optical Planar Waveguide.

Authors:  Ali Al-Jawdah; Alexei Nabok; Radhyah Jarrah; Alan Holloway; Anna Tsargorodska; Eszter Takacs; Andras Szekacs
Journal:  Toxins (Basel)       Date:  2018-07-03       Impact factor: 4.546

2.  Highly sensitive label-free in vitro detection of aflatoxin B1 in an aptamer assay using optical planar waveguide operating as a polarization interferometer.

Authors:  Ali Al-Jawdah; Alexei Nabok; Hisham Abu-Ali; Gaelle Catanante; Jean-Louis Marty; Andras Szekacs
Journal:  Anal Bioanal Chem       Date:  2019-08-07       Impact factor: 4.142

3.  Monolithically integrated broad-band Mach-Zehnder interferometers for highly sensitive label-free detection of biomolecules through dual polarization optics.

Authors:  A Psarouli; A Salapatas; A Botsialas; P S Petrou; I Raptis; E Makarona; G Jobst; K Tukkiniemi; M Sopanen; R Stoffer; S E Kakabakos; K Misiakos
Journal:  Sci Rep       Date:  2015-12-02       Impact factor: 4.379

  3 in total