Literature DB >> 20724419

Measurement of femoral torsion by ultrasound and magnetic resonance imaging: concurrent validity.

Kornelia Kulig1, Kellee Harper-Hanigan, Richard B Souza, Christopher M Powers.   

Abstract

BACKGROUND: Abnormal femoral torsion has been linked to osteoarthritis in the knee as well as to patellofemoral pain. Inexpensive, valid, and reliable methods for assessing femoral torsion are needed. Ultrasound (US) is a noninvasive and clinically accessible method that can be used for the assessment of bone morphology, such as femoral torsion.
OBJECTIVE: The objective of this study was to determine the concurrent validity of US for the measurement of femoral torsion with a reference method, magnetic resonance imaging (MRI).
DESIGN: Repeated measurements of femoral torsion were obtained with US and MRI in a laboratory setting.
METHODS: Twenty-eight people (4 men, 24 women; mean age=26.8 years [SD=4.0 years], mean body height=170.3 cm [SD=8.0 cm], mean body weight=64.7 kg [SD=9.8 kg]) participated in this study. T1-weighted axial oblique images of the femoral neck and epicondylar axis were acquired with a 1.5-T magnetic resonance system. Ultrasonographic measurements then were obtained by a tilting technique with a linear transducer that was 4.5 cm long and operated at a frequency of 10 MHz and a depth of 5 cm.
RESULTS: The average angles of anteversion measured by US and by MRI were 20.7 degrees (SD=11.0) and 19 degrees (SD=11.3), respectively. The reliability, reported as the intraclass correlation coefficient [ICC (2,1)], of repeated measurements of in vivo femoral torsion by US was .98. The reliability [ICC (2,1)] of magnetic resonance image analysis was .96. The standard error of the measurement for US was 2.2 degrees, and that for MRI was 1.9 degrees. The concurrent validity of US with MRI (R(2)) was .93 (r=.96). LIMITATIONS: Obtaining measurements by US requires appropriate training before data collection.
CONCLUSIONS: Ultrasound measurement of femoral torsion has high concurrent validity with in vivo MRI and may be used when an assessment of bony morphology is needed but MRI is not available.

Entities:  

Mesh:

Year:  2010        PMID: 20724419     DOI: 10.2522/ptj.20090391

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  7 in total

1.  The physiological range of femoral antetorsion.

Authors:  Sebastian Decker; Eduardo M Suero; Nael Hawi; Christian W Müller; Christian Krettek; Musa Citak
Journal:  Skeletal Radiol       Date:  2013-07-16       Impact factor: 2.199

2.  Reliability and Validity of a 1-Person Technique to Measure Humeral Torsion Using Ultrasound.

Authors:  Daniel C Hannah; Jason S Scibek; Christopher R Carcia; Amy L Phelps
Journal:  J Athl Train       Date:  2018-07-05       Impact factor: 2.860

3.  Does electromagnetic-manual guided distal locking influence rotational alignment in antegrade femoral nailing?

Authors:  Mert Ciftdemir; Sedat A Tuncel; Mert Ozcan; Cem Copuroglu; Murat Erem
Journal:  Int Orthop       Date:  2014-12-16       Impact factor: 3.075

4.  Bony abnormalities of the hip joint: a new comprehensive, reliable and radiation-free measurement method using magnetic resonance imaging.

Authors:  Marcie Harris-Hayes; Paul K Commean; Jacqueline D Patterson; John C Clohisy; Travis J Hillen
Journal:  J Hip Preserv Surg       Date:  2014

5.  Reliability of an Integrated Ultrasound and Stereophotogrammetric System for Lower Limb Anatomical Characterisation.

Authors:  Frederick Greatrex; Erica Montefiori; Thomas Grupp; Josef Kozak; Claudia Mazzà
Journal:  Appl Bionics Biomech       Date:  2017-06-19       Impact factor: 1.781

Review 6.  Femoral anteversion: significance and measurement.

Authors:  Matteo Scorcelletti; Neil D Reeves; Jörn Rittweger; Alex Ireland
Journal:  J Anat       Date:  2020-06-24       Impact factor: 2.610

7.  Femoral Neck Anteversion and Neck Shaft Angles: Determination and their Clinical Implications in Fetuses of Different Gestational Ages.

Authors:  A D Souza; V H Ankolekar; S Padmashali; A Das; Asd Souza; M Hosapatna
Journal:  Malays Orthop J       Date:  2015-07
  7 in total