Literature DB >> 20724016

Factors influencing the accuracy of the plating method used to enumerate low numbers of viable micro-organisms in food.

I Jongenburger1, M W Reij, E P J Boer, L G M Gorris, M H Zwietering.   

Abstract

This study aims to assess several factors that influence the accuracy of the plate count technique to estimate low numbers of micro-organisms in liquid and solid food. Concentrations around 10CFU/mL or 100CFU/g in the original sample, which can still be enumerated with the plate count technique, are considered as low numbers. The impact of low plate counts, technical errors, heterogeneity of contamination and singular versus duplicate plating were studied. Batches of liquid and powdered milk were artificially contaminated with various amounts of Cronobacter sakazakii strain ATCC 29544 to create batches with accurately known levels of contamination. After thoroughly mixing, these batches were extensively sampled and plated in duplicate. The coefficient of variation (CV) was calculated for samples from both batches of liquid and powdered product as a measure of the dispersion within the samples. The impact of technical errors and low plate counts were determined theoretically, experimentally, as well as with Monte Carlo simulations. CV-values for samples of liquid milk batches were found to be similar to their theoretical CV-values established by assuming Poisson distribution of the plate counts. However, CV-values of samples of powdered milk batches were approximately five times higher than their theoretical CV-values. In particular, powdered milk samples with low numbers of Cronobacter spp. showed much more dispersion than expected which was likely due to heterogeneity. The impact of technical errors was found to be less prominent than that of low plate counts or of heterogeneity. Considering the impact of low plate counts on accuracy, it would be advisable to keep to a lower limit for plate counts of 25 colonies/plate rather than to the currently advocated 10 colonies/plate. For a powdered product with a heterogeneous contamination, it is more accurate to use 10 plates for 10 individual samples than to use the same 10 plates for 5 samples plated in duplicate. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20724016     DOI: 10.1016/j.ijfoodmicro.2010.07.025

Source DB:  PubMed          Journal:  Int J Food Microbiol        ISSN: 0168-1605            Impact factor:   5.277


  2 in total

1.  Potentiating the Anti-Tuberculosis Efficacy of Peptide Nucleic Acids through Combinations with Permeabilizing Drugs.

Authors:  Karishma Berta Cotta; Saptarshi Ghosh; Sarika Mehra
Journal:  Microbiol Spectr       Date:  2022-02-16

2.  Absolute Enumeration of Probiotic Strains Lactobacillus acidophilus NCFM® and Bifidobacterium animalis subsp. lactis Bl-04 ® via Chip-Based Digital PCR.

Authors:  Sarah J Z Hansen; Wesley Morovic; Martha DeMeules; Buffy Stahl; Connie W Sindelar
Journal:  Front Microbiol       Date:  2018-04-11       Impact factor: 5.640

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.