Literature DB >> 20723995

Endothelial keratoplasty: the relationship between donor tissue storage time and donor endothelial survival.

Mark A Terry1, Neda Shamie, Michael D Straiko, Daniel J Friend, David Davis-Boozer.   

Abstract

PURPOSE: To evaluate the relationship between storage time in Optisol GS (Bausch & Lomb, St. Louis, MO) and postoperative cell loss after Descemet's stripping automated endothelial keratoplasty (DSAEK) surgery.
DESIGN: Retrospective analysis of a noncomparative, interventional case series. PARTICIPANTS: Three hundred sixty-two eyes of 265 patients undergoing DSAEK surgery for Fuchs' endothelial dystrophy.
METHODS: Storage times (death to surgery) of donor tissue were recorded for 362 eyes undergoing DSAEK surgery. Donor cell loss at 6, 12, and 24 months was recorded. Analysis of storage times with endothelial cell loss was performed using a Pearson correlation coefficient and an independent samples Student t test. MAIN OUTCOME MEASURES: Percentage of donor endothelial cell loss as measured by specular microscopy of central endothelial cell density (ECD).
RESULTS: The mean storage time was 98.95 ± 33 hours (range, 20.65-186.02 hours). The mean percent endothelial cell loss from before to after surgery was 29 ± 16% at 6 months (n = 362), 31 ± 16% at 12 months (n = 263), and 32 ± 20% at 24 months (n = 98). Storage time did not correlate significantly with endothelial cell loss at any postoperative time point (6 months: r = -0.047, P = 0.373; 12 months: r = -0.023, P = 0.709; 24 months: r = -0.14, P = 0.169). The mean cell loss for corneas stored 0 to 4 days (n = 55) was 32 ± 17% at 2 years and the mean cell loss for corneas stored for more than 4 days (n = 43) was 30 ± 18% at 2 years (P = 0.57). At the extremes of storage time, 10 corneas stored for the shortest time (1.5 days) had a 1-year cell loss of 33% and 10 corneas stored for the longest time (7 days) had a 1-year cell loss of 30% (P = 0.45).
CONCLUSIONS: No correlation was found between the characteristic of storage time and the decline of ECD. Surgeons should not make special requests to the eye bank for short storage times with the hope of improving donor endothelial survival. The upper limit of donor storage time as it relates to acceptable postoperative endothelial cell loss is not known.
Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20723995     DOI: 10.1016/j.ophtha.2010.04.029

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  10 in total

Review 1.  Graft survival and endothelial outcomes in the new era of endothelial keratoplasty.

Authors:  Sanjay V Patel
Journal:  Exp Eye Res       Date:  2011-06-15       Impact factor: 3.467

2.  Donor, Recipient, and Operative Factors Associated with Graft Success in the Cornea Preservation Time Study.

Authors:  Mark A Terry; Anthony J Aldave; Loretta B Szczotka-Flynn; Wendi Liang; Allison R Ayala; Maureen G Maguire; Christopher Croasdale; Yassine J Daoud; Steven P Dunn; Caroline K Hoover; Marian S Macsai; Thomas F Mauger; Sudeep Pramanik; George O D Rosenwasser; Jennifer Rose-Nussbaumer; R Doyle Stulting; Alan Sugar; Elmer Y Tu; David D Verdier; Sonia H Yoo; Jonathan H Lass
Journal:  Ophthalmology       Date:  2018-08-09       Impact factor: 12.079

Review 3.  Eye-bank preparation of endothelial tissue.

Authors:  Grace E Boynton; Maria A Woodward
Journal:  Curr Opin Ophthalmol       Date:  2014-07       Impact factor: 3.761

4.  Endothelial cell counts after Descemet's stripping automated endothelial keratoplasty versus penetrating keratoplasty in Asian eyes.

Authors:  Marcus Ang; Jodhbir S Mehta; Arundhati Anshu; Hon Kiat Wong; Hla M Htoon; Donald Tan
Journal:  Clin Ophthalmol       Date:  2012-04-03

Review 5.  Descemet's Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices.

Authors:  Salman Nasir Khan; Panos S Shiakolas; Venkateswara Vinod Mootha
Journal:  J Ophthalmic Vis Res       Date:  2015 Oct-Dec

6.  Factors Influencing Graft Endothelial Cell Density after Descemet Stripping Automated Endothelial Keratoplasty.

Authors:  Mohammad Ali Javadi; Sepehr Feizi; Roya Jafari; Seyed Bagher Hosseini; Sharareh Safapour
Journal:  J Ophthalmic Vis Res       Date:  2018 Jan-Mar

7.  Corneal Endothelial Cell Integrity in Precut Human Donor Corneas Enhanced by Autocrine Vasoactive Intestinal Peptide.

Authors:  Shay-Whey M Koh; Timothy Coll; Dante Gloria; Nicholas Sprehe
Journal:  Cornea       Date:  2017-04       Impact factor: 2.651

8.  Outcomes of descemet stripping automated endothelial keratoplasty using imported donor corneas.

Authors:  Kaevalin Lekhanont; Kavin Vanikieti; Nutthida Nimvorapun; Varintorn Chuckpaiwong
Journal:  BMC Ophthalmol       Date:  2017-04-05       Impact factor: 2.209

9.  Prospective evaluation of clinical outcomes between pre-cut corneal grafts prepared using a manual or automated technique: with one-year follow-up.

Authors:  Marc B Muijzer; Chantal M van Luijk; Antoon J van den Bogaerdt; Piet J Kruit; Esther Groeneveld-van Beek; Gerrit R J Melles; Robert P L Wisse
Journal:  Acta Ophthalmol       Date:  2019-02-25       Impact factor: 3.761

10.  A standardized methodology for longitudinal assessment of corneal endothelial morphometry in eye banked corneas.

Authors:  Zala Lužnik; Zhongmou Sun; Jia Yin; Beth Ann Benetz; Jonathan H Lass; Reza Dana
Journal:  J Biol Methods       Date:  2019-11-20
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.