Imaging based optofluidic air flow meter with polymer interferometers defined by soft lithography.

Wuzhou Song1, Demetri Psaltis.   

Abstract

We present an optofluidic chip with integrated polymer interferometers for measuring both the microfluidic air pressure and flow rate. The chip contains a microfluidic circuit and optical cavities on a polymer which was defined by soft lithography. The pressure can be read out by imaging the interference patterns of the cavities. The air flow rate was then calculated from the differential pressure across a microfluidic Venturi circuit. Air flow rate measurement in the range of 0-2mg/second was demonstrated. This device provides a simple and versatile way for in situ measuring the microscale air pressure and flow on chip.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20721045     DOI: 10.1364/OE.18.016561

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  2 in total

1.  Optofluidic membrane interferometer: An imaging method for measuring microfluidic pressure and flow rate simultaneously on a chip.

Authors:  Wuzhou Song; Demetri Psaltis
Journal:  Biomicrofluidics       Date:  2011-11-30       Impact factor: 2.800

2.  Measurement and control of pressure driven flows in microfluidic devices using an optofluidic flow sensor.

Authors:  Mohammad Sadegh Cheri; Hamidreza Shahraki; Jalal Sadeghi; Mohammadreza Salehi Moghaddam; Hamid Latifi
Journal:  Biomicrofluidics       Date:  2014-10-24       Impact factor: 2.800