Literature DB >> 20719670

Reliability of non-normalized and normalized integrated EMG during maximal isometric contractions in females.

D Zakaria1, J F Kramer, K L Harburn.   

Abstract

The purpose of this investigation was to examine the test-retest reliability of non-normalized (absolute or raw units of mV . s) and normalized (percentage ratio) scores using integrated electromyography (IEMG) in voluntary maximal isometric contractions. Bipolar surface electrodes on the vastus medialis (VM) and vastus lateralis (VL) muscles were used to record IEMG (mV . s) on two occasions, 2-8 days apart. While, positioned supine, 20 healthy young women (mean age 24 +/- 2 yr) performed: (a) maximal voluntary unilateral quadriceps setting (QS) (i.e. isometric knee extension with the knee in 0 degrees ) with the ankle joint in a neutral position and the ankle musculature relaxed, and (b) maximal unilateral OS with the ankle joint in maximal dorsiflexion and the ankle dorsiflexors maximally contracted (QSD). The QS exercise was used to normalize IEMG (QSD: QS ratio for each of the two muscle heads) and the VM muscle was also used to normalize IEMG to the other head of the vasti (VL: VM ratio for each exercise). Reliability coefficients were excellent for test-retest reliability of non-normalized IEMG (mV . s) and for IEMG normalized to another muscle: (intraclass correlation coefficients (ICCs) > 0.86). However, IEMG normalized to another exercise was characterized by poor reliability (ICCs < 0.34), even when determined as the reliability of data averaged over two occasions. Regardless of whether absolute or normalized IEMG was used, 95% confidence intervals were wide, suggesting that precise, interday prediction of an individual's performance using the present protocol is questionnable.

Entities:  

Year:  1996        PMID: 20719670     DOI: 10.1016/1050-6411(95)00025-9

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  5 in total

1.  Can Kinesio Taping® influence the electromyographic signal intensity of trunk extensor muscles in patients with chronic low back pain? A randomized controlled trial.

Authors:  Leandro Garcia Pires; Rosimeire Simprini Padula; Maurício Antônio Da Luz Junior; Irlei Santos; Matheus Oliveira Almeida; Shaiane Silva Tomazoni; Lucíola Cunha Menezes Costa; Leonardo Oliveira Pena Costa
Journal:  Braz J Phys Ther       Date:  2019-12-15       Impact factor: 3.377

2.  The effect of different decline angles on the biomechanics of double limb squats and the implications to clinical and training practice.

Authors:  Jim Richards; James Selfe; Jonathan Sinclair; Karen May; Gavin Thomas
Journal:  J Hum Kinet       Date:  2016-09-10       Impact factor: 2.193

3.  Inter-day reliability of surface electromyography recordings of the lumbar part of erector spinae longissimus and trapezius descendens during box lifting.

Authors:  Mikkel Brandt; Lars Louis Andersen; Afshin Samani; Markus Due Jakobsen; Pascal Madeleine
Journal:  BMC Musculoskelet Disord       Date:  2017-12-11       Impact factor: 2.362

4.  Normalization of the trapezius sEMG signal - a reliability study on women with and without neck-shoulder pain.

Authors:  Marina Machado Cid; Leticia Bergamin Januario; Gisele Garcia Zanca; Stela Marcia Mattiello; Ana Beatriz Oliveira
Journal:  Braz J Phys Ther       Date:  2017-09-29       Impact factor: 3.377

5.  Reduced Vastus Medialis/Lateralis EMG Ratio in Volleyballers with Chronic Knee Pain on Sports-Specific Surfaces: A Pilot Study.

Authors:  Christina Frese; Dieter Bubeck; Wilfried Alt
Journal:  Int J Environ Res Public Health       Date:  2022-08-11       Impact factor: 4.614

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.