Literature DB >> 20719493

Biosensors coated with sulfated polysaccharides for the detection of hepatocyte growth factor/scatter factor in cell culture medium.

Manuel Berger1, Alexander Welle, Eric Gottwald, Michael Rapp, Kerstin Länge.   

Abstract

Process control methods for cell culture bioreactors include on-line monitoring of protein concentrations. Bioreactor samples typically contain high amounts of different proteins. The direct detection of a single protein in this complex medium is a challenging task within the development of biosensors with label-free detection. We introduce the development of a mass-sensitive biosensor based on surface acoustic waves (SAW) for the detection of hepatocyte growth factor/scatter factor (HGF/SF) in the serum containing medium of a miniaturized bioreactor for culturing hepatocytes. The specificity of the biosensor was obtained following two approaches. In the first approach, antibodies against HGF (anti-HGF) were immobilized covalently via an intermediate layer of dicarboxy polyethylene glycol on the biosensor surface. In the second approach, dextran sulfate and fucoidan were used as sensor coatings exploiting the fact that HGF binds specifically to those sulfated polysaccharides. Performing HGF assays, similar results were obtained using biosensors coated with dextran sulfate and biosensors coated with anti-HGF. Even higher sensor signals were obtained using biosensors coated with fucoidan, particularly at 37°C. Therefore, biosensor coatings based on biospecific sulfated polysaccharides offer a simple and cost-saving alternative compared to the commonly used coating with antibodies.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20719493     DOI: 10.1016/j.bios.2010.07.065

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  Recent Advances in the Use of Algal Polysaccharides for Skin Wound Healing.

Authors:  Suneel Kumar; Ileana Marrero-Berrios; Maciej Kabat; Francois Berthiaume
Journal:  Curr Pharm Des       Date:  2019       Impact factor: 3.116

2.  Surface acoustic wave devices for chemical sensing and microfluidics: A review and perspective.

Authors:  David B Go; Masood Z Atashbar; Zeinab Ramshani; Hsueh-Chia Chang
Journal:  Anal Methods       Date:  2017-06-13       Impact factor: 2.896

3.  NCO-sP(EO-stat-PO) coatings on gold sensors--a QCM study of hemocompatibility.

Authors:  Stefan Sinn; Mirjam Eichler; Lothar Müller; Daniel Bünger; Jürgen Groll; Gerhard Ziemer; Frank Rupp; Hinnak Northoff; Jürgen Geis-Gerstorfer; Frank K Gehring; Hans P Wendel
Journal:  Sensors (Basel)       Date:  2011-05-13       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.