Laboratory confirmed polymethyl-methacrylate (Palacos)-hypersensitivity after cranioplasty.

Oliver P Gautschi1, Christopher L Schlett, Jean-Yves Fournier, Dieter Cadosch.   

Abstract

Polymethyl-methacrylate (PMMA) as part of bone cement is a widely used material in the context of orthopaedic implants and also in cranioplasty. Although PMMA is characterised by excellent biocompatibility with low intrinsic toxicity and inflammatory activation, a minor portion of patients develop allergic reactions. We present the case of a 39-year-old woman with an increasing headache and a corresponding erythema over the parieto-occipital cranioplasty, which was performed 42 days prior using a PMMA compound. A patch test specific for bone cement components confirmed the diagnosis of a PMMA delayed-type hypersensitivity reaction. The prevalence of allergic reactions to bone cement components are known to vary from between 0.6% and 1.6%, however no adequate, pre-interventional diagnostic tool is currently available. Therefore, physicians are required to consider this differential diagnosis even after an extremely delayed onset of symptoms. This case describes the first ever-reported case in the literature of hypersensitivity to bone cement cranioplasty.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20719430     DOI: 10.1016/j.clineuro.2010.07.013

Source DB:  PubMed          Journal:  Clin Neurol Neurosurg        ISSN: 0303-8467            Impact factor:   1.876


  7 in total

1.  Gentamicin-Loaded Polysaccharide Membranes for Prevention and Treatment of Post-operative Wound Infections in the Skeletal System.

Authors:  Urszula Cibor; Małgorzata Krok-Borkowicz; Monika Brzychczy-Włoch; Łucja Rumian; Krzysztof Pietryga; Dominika Kulig; Wojciech Chrzanowski; Elżbieta Pamuła
Journal:  Pharm Res       Date:  2017-06-21       Impact factor: 4.200

2.  Cranioplasty using presurgically fabricated presterilised polymethyl methacrylate plate by a simple, cost-effective technique on patients with and without original bone flap: study on 29 patients.

Authors:  G M Sharavanan; Suresh Jayabalan; K Rajasukumaran; Ganesh Veerasekar; G Sathya
Journal:  J Maxillofac Oral Surg       Date:  2014-08-28

Review 3.  Characterisation of Selected Materials in Medical Applications.

Authors:  Kacper Kroczek; Paweł Turek; Damian Mazur; Jacek Szczygielski; Damian Filip; Robert Brodowski; Krzysztof Balawender; Łukasz Przeszłowski; Bogumił Lewandowski; Stanisław Orkisz; Artur Mazur; Grzegorz Budzik; Józef Cebulski; Mariusz Oleksy
Journal:  Polymers (Basel)       Date:  2022-04-09       Impact factor: 4.967

4.  Crystallization of l-alanine in the presence of additives on a circular PMMA platform designed for metal-assisted and microwave-accelerated evaporative crystallization.

Authors:  Anginelle M Alabanza; Muzaffer Mohammed; Kadir Aslan
Journal:  CrystEngComm       Date:  2012-12-21       Impact factor: 3.545

5.  A Polymer for Application as a Matrix Phase in a Concept of In Situ Curable Bioresorbable Bioactive Load-Bearing Continuous Fiber Reinforced Composite Fracture Fixation Plates.

Authors:  Artem Plyusnin; Jingwei He; Cindy Elschner; Miho Nakamura; Julia Kulkova; Axel Spickenheuer; Christina Scheffler; Lippo V J Lassila; Niko Moritz
Journal:  Molecules       Date:  2021-02-26       Impact factor: 4.411

6.  Biomechanical Evaluation of Patient-Specific Polymethylmethacrylate Cranial Implants for Virtual Surgical Planning: An In-Vitro Study.

Authors:  Bilal Msallem; Michaela Maintz; Florian S Halbeisen; Simon Meyer; Guido R Sigron; Neha Sharma; Shuaishuai Cao; Florian M Thieringer
Journal:  Materials (Basel)       Date:  2022-03-07       Impact factor: 3.623

7.  Epidural Effusion as Allergic Reaction Following Polyetheretherketone Cranioplasty: An Illustrative Case and Review of the Literature.

Authors:  Lisa B Shields; Meena Vessell; Ian S Mutchnick
Journal:  Cureus       Date:  2022-01-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.