Literature DB >> 20718803

Rapid method for direct identification of bacteria in urine and blood culture samples by matrix-assisted laser desorption ionization time-of-flight mass spectrometry: intact cell vs. extraction method.

L Ferreira1, F Sánchez-Juanes, J L Muñoz-Bellido, J M González-Buitrago.   

Abstract

Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a fast and reliable technology for the identification of microorganisms with proteomics approaches. Here, we compare an intact cell method and a protein extraction method before application on the MALDI plate for the direct identification of microorganisms in both urine and blood culture samples from clinical microbiology laboratories. The results show that the intact cell method provides excellent results for urine and is a good initial method for blood cultures. The extraction method complements the intact cell method, improving microorganism identification from blood culture. Thus, we consider that MALDI-TOF MS performed directly on urine and blood culture samples, with the protocols that we propose, is a suitable technique for microorganism identification, as compared with the routine methods used in the clinical microbiology laboratory.
© 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.

Entities:  

Mesh:

Year:  2010        PMID: 20718803     DOI: 10.1111/j.1469-0691.2010.03339.x

Source DB:  PubMed          Journal:  Clin Microbiol Infect        ISSN: 1198-743X            Impact factor:   8.067


  33 in total

1.  Comparison of the MALDI Biotyper system using Sepsityper specimen processing to routine microbiological methods for identification of bacteria from positive blood culture bottles.

Authors:  Blake W Buchan; Katherine M Riebe; Nathan A Ledeboer
Journal:  J Clin Microbiol       Date:  2011-12-07       Impact factor: 5.948

2.  Comparison of an in-house method and the commercial Sepsityper™ kit for bacterial identification directly from positive blood culture broths by matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry.

Authors:  D Martiny; A Dediste; O Vandenberg
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-02-25       Impact factor: 3.267

Review 3.  Matrix-assisted laser desorption ionization-time of flight mass spectrometry: a fundamental shift in the routine practice of clinical microbiology.

Authors:  Andrew E Clark; Erin J Kaleta; Amit Arora; Donna M Wolk
Journal:  Clin Microbiol Rev       Date:  2013-07       Impact factor: 26.132

4.  Improved identification of yeast species directly from positive blood culture media by combining Sepsityper specimen processing and Microflex analysis with the matrix-assisted laser desorption ionization Biotyper system.

Authors:  Yingjun Yan; Ying He; Thomas Maier; Criziel Quinn; Gongyi Shi; Haijing Li; Charles W Stratton; Markus Kostrzewa; Yi-Wei Tang
Journal:  J Clin Microbiol       Date:  2011-05-04       Impact factor: 5.948

5.  A differential centrifugation protocol and validation criterion for enhancing mass spectrometry (MALDI-TOF) results in microbial identification using blood culture growth bottles.

Authors:  G A March-Rosselló; M F Muñoz-Moreno; M C García-Loygorri-Jordán de Urriés; M A Bratos-Pérez
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-12-30       Impact factor: 3.267

6.  Rapid urine preparation prior to identification of uropathogens by MALDI-TOF MS.

Authors:  L Veron; S Mailler; V Girard; B H Muller; G L'Hostis; C Ducruix; A Lesenne; A Richez; H Rostaing; V Lanet; S Ghirardi; A van Belkum; F Mallard
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-06-09       Impact factor: 3.267

7.  Biosensor diagnosis of urinary tract infections: a path to better treatment?

Authors:  Kathleen E Mach; Pak Kin Wong; Joseph C Liao
Journal:  Trends Pharmacol Sci       Date:  2011-03-31       Impact factor: 14.819

8.  Rapid detection of Salmonella sp. by means of a combination of selective enrichment broth and MALDI-TOF MS.

Authors:  K Sparbier; U Weller; C Boogen; M Kostrzewa
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-08-13       Impact factor: 3.267

9.  Direct Identification of Pathogens in Urine by Use of a Specific Matrix-Assisted Laser Desorption Ionization-Time of Flight Spectrum Database.

Authors:  Lucile Pinault; Eric Chabrière; Didier Raoult; Florence Fenollar
Journal:  J Clin Microbiol       Date:  2019-03-28       Impact factor: 5.948

10.  MALDI-TOF MS performance compared to direct examination, culture, and 16S rDNA PCR for the rapid diagnosis of bone and joint infections.

Authors:  E Lallemand; G Coiffier; C Arvieux; E Brillet; P Guggenbuhl; A Jolivet-Gougeon
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2016-03-04       Impact factor: 3.267

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.