Literature DB >> 20716717

Automatic remote monitoring of implantable cardioverter-defibrillator lead and generator performance: the Lumos-T Safely RedUceS RouTine Office Device Follow-Up (TRUST) trial.

Niraj Varma1, Justin Michalski, Andrew E Epstein, Robert Schweikert.   

Abstract

BACKGROUND: Monitoring performance of implantable cardioverter-defibrillator (ICD) generators and leads is important. Methods available are with in-person evaluations or by automatic remote home monitoring (HM). These were prospectively evaluated and compared in the TRUST trial. The HM technology tested performed daily self-checks and databasing with rapid event notifications for out-of-range (including asymptomatic) conditions. METHODS AND
RESULTS: Patients (n=1339) were randomly assigned after ICD implant 2:1 to HM or to conventional groups. Both groups underwent scheduled checks every 3 months and were followed for 15 months. In HM, in-person office visits were scheduled at 3 and 15 months. At 6, 9, and 12 months, HM only was used with subsequent office visits if necessary. Between these time points, ICDs triggered event notifications for system integrity problems. Patients randomly assigned to conventional follow-up were evaluated with office visits only. HM and conventional patients were similar (age, 63.3±12.8 versus 64.0±12.1 years; 72.0% versus 73.1% male; New York Heart Association II class, 55.9% versus 60.4%; left ventricular ejection fraction, 29.0±10.7% versus 28.5±9.8%; coronary artery disease, 64.8% versus 71.7%; primary prevention, 72.2% versus 73.8%; DDD devices, 57.8% versus 56.6%). Four patients crossed over from conventional to HM because of advisories. Scheduled checks were more successfully accomplished in HM (92.7% versus 89.2% in conventional, P<0.001). Sixty-two device-related events (53 in HM versus 9 in conventional) were observed in 46 patients (40 [4.4%] in HM versus 6 [1.39%] in conventional, P=0.004). Forty-seven percent were asymptomatic. HM detected generator and lead problems earlier (HM versus conventional: median, 1 versus 5 days; P=0.05). A total of 20 device problems (eg, lead fracture, elective replacement indicators) requiring surgical revision (0.012 per patient-year) were found, 15 in HM and 5 in the conventional groups. Other events were managed nonsurgically (eg, reprogramming, initiation of antiarrhythmics).
CONCLUSIONS: ICD lead and generator malfunction was infrequent and often asymptomatic. Only a minority of detected events required surgical intervention. Automatic HM enhanced discovery, permitted prompt detection, and facilitated management decisions. Longitudinal parameter trending, with component function evaluated daily by remote monitoring, may enable long-term performance assessment. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov. Unique identifier: NCT00336284.

Entities:  

Mesh:

Year:  2010        PMID: 20716717     DOI: 10.1161/CIRCEP.110.951962

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  37 in total

1.  ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs).

Authors:  Sergio Dubner; Angelo Auricchio; Jonathan S Steinberg; Panos Vardas; Peter Stone; Josep Brugada; Ryszard Piotrowicz; David L Hayes; Paulus Kirchhof; Günter Breithardt; Wojciech Zareba; Claudio Schuger; Mehmet K Aktas; Michal Chudzik; Suneet Mittal; Niraj Varma
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-01       Impact factor: 1.468

2.  [Lead survival and complications (except infections). Are we doing better nowadays?].

Authors:  Martin Seifert; Michael Neuss; Maren Schöpp; Cornel Koban; Christian Butter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-08-06

3.  REmote SUpervision to Decrease HospitaLization RaTe. Unified and integrated platform for data collected from devices manufactured by different companies: Design and rationale of the RESULT study.

Authors:  Mateusz Tajstra; Adam Sokal; Arkadiusz Gwóźdź; Marcin Wilczek; Adam Gacek; Konrad Wojciechowski; Elżbieta Gadula-Gacek; Elżbieta Adamowicz-Czoch; Katarzyna Chłosta-Niepiekło; Krzysztof Milewski; Piotr Rozentryt; Zbigniew Kalarus; Mariusz Gąsior; Lech Poloński
Journal:  Ann Noninvasive Electrocardiol       Date:  2016-12-25       Impact factor: 1.468

Review 4.  [Implantable cardioverter defibrillator].

Authors:  C Stellbrink; D Andresen; D Böcker; T Lewalter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-03

5.  Implantable cardioverter defibrillator remote monitoring is well accepted and easy to use during long-term follow-up.

Authors:  Loredana Morichelli; Antonio Porfili; Laura Quarta; Anna Sassi; Renato Pietro Ricci
Journal:  J Interv Card Electrophysiol       Date:  2014-09-26       Impact factor: 1.900

6.  Is There a Future for Remote Cardiac Implantable Electronic Device Management?

Authors:  Haran Burri
Journal:  Arrhythm Electrophysiol Rev       Date:  2017-08

7.  A prospective comparison of remote monitoring systems in implantable cardiac defibrillators: potential effects of frequency of transmissions.

Authors:  Ermenegildo de Ruvo; Luigi Sciarra; Anna Maria Martino; Marco Rebecchi; Renzo Venanzio Iulianella; Francesco Sebastiani; Alessandro Fagagnini; Alessio Borrelli; Antonio Scarà; Domenico Grieco; Claudia Tota; Federica Stirpe; Leonardo Calò
Journal:  J Interv Card Electrophysiol       Date:  2016-01       Impact factor: 1.900

8.  Organizational model and reactions to alerts in remote monitoring of cardiac implantable electronic devices: A survey from the Home Monitoring Expert Alliance project.

Authors:  Gabriele Zanotto; Antonio D'Onofrio; Paolo Della Bella; Francesco Solimene; Ennio C Pisanò; Saverio Iacopino; Cristina Dondina; Daniele Giacopelli; Alessio Gargaro; Renato P Ricci
Journal:  Clin Cardiol       Date:  2018-12-15       Impact factor: 2.882

9.  2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society.

Authors:  Niraj Varma; Iwona Cygankiewicz; Mintu P Turakhia; Hein Heidbuchel; Yu-Feng Hu; Lin Yee Chen; Jean-Philippe Couderc; Edmond M Cronin; Jerry D Estep; Lars Grieten; Deirdre A Lane; Reena Mehra; Alex Page; Rod Passman; Jonathan P Piccini; Ewa Piotrowicz; Ryszard Piotrowicz; Pyotr G Platonov; Antonio Luiz Ribeiro; Robert E Rich; Andrea M Russo; David Slotwiner; Jonathan S Steinberg; Emma Svennberg
Journal:  Circ Arrhythm Electrophysiol       Date:  2021-02-12

10.  Use of remote monitoring in the management of system-related complications in implantable defibrillator patients.

Authors:  D A M J Theuns; L Jordaens
Journal:  Neth Heart J       Date:  2012-02       Impact factor: 2.380

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.