Use of transendoscopic contact neodymium:yttrium aluminum garnet laser to drain dorsal epiglottic abscesses in two horses.

E P Tulleners1.   

Abstract

A submucosal abscess, located on the dorsal surface of the epiglottis, was diagnosed in 2 Thoroughbred racehorses by use of endoscopy. Both horses had exercise intolerance. One horse had intermittent dorsal displacement of the soft palate, coughed while eating and galloping, and made an abnormal respiratory noise. Both abscesses were drained transendoscopically by use of a contact neodymium:yttrium aluminum garnet laser. Eleven days after surgery, the surgical sites appeared to have healed. Clinical signs resolved permanently, and both horses returned to successful racing careers.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2071477

Source DB:  PubMed          Journal:  J Am Vet Med Assoc        ISSN: 0003-1488            Impact factor:   1.936


  1 in total

1.  Septic epiglottic chondritis with abscessation in 2 young Thoroughbred racehorses.

Authors:  Tomas Infernuso; Ashlee E Watts; Norm G Ducharme
Journal:  Can Vet J       Date:  2006-10       Impact factor: 1.008