Literature DB >> 20711488

Background Current Elimination in Thin Layer Ion-Selective Membrane Coulometry.

Ewa Grygolowicz-Pawlak1, Eric Bakker.   

Abstract

A promising method for the elimination of undesired capacitive currents in view of realizing a potentially calibration free coulometric ion detection system is presented. The coulometric cell is composed of a porous polypropylene tube doped with a liquid calcium-selective membrane and a silver/silver chloride wire as an inner electrode, forming a thin layer sample between wire and tubing. The total charge passed through the system during potential controlled electrolysis of the thin layer sample is indeed found to be proportional to the amount of calcium present, but non-Faradaic processes do contribute to the obtained signal. We introduce here a multi-pulse procedure that allows one to perform a second excitation pulse at the same excitation potential after exhaustive ion transfer voltammetry of calcium has taken place. The intercept of the calibration curve after background subtraction is found as 20.6 +/- 0.6 muC, significantly lower than the value of 54.1 +/- 0.8 muC for the uncorrected curve. Changes in sample temperature (from 23 degrees C to 38 degrees C) did equally not affect the background corrected coulometric readings, supporting that the procedure renders the readout principle more robust.

Entities:  

Year:  2010        PMID: 20711488      PMCID: PMC2919778          DOI: 10.1016/j.elecom.2010.06.017

Source DB:  PubMed          Journal:  Electrochem commun        ISSN: 1388-2481            Impact factor:   4.724


  7 in total

1.  Complete electrolysis using a microflow cell with an oil/water interface.

Authors:  Shigeo Sawada; Masaru Taguma; Takashi Kimoto; Hiroki Hotta; Toshiyuki Osakai
Journal:  Anal Chem       Date:  2002-03-01       Impact factor: 6.986

2.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics.

Authors:  Eric Bakker; Philippe Bühlmann; Ernö Pretsch
Journal:  Chem Rev       Date:  1997-12-18       Impact factor: 60.622

3.  Voltammetry of the phase transfer of polypeptide protamines across polarized liquid/liquid interfaces.

Authors:  Shigeru Amemiya; Xiting Yang; Tracy L Wazenegger
Journal:  J Am Chem Soc       Date:  2003-10-01       Impact factor: 15.419

4.  Reverse current pulse method to restore uniform concentration profiles in ion-selective membranes. 2. Comparison of the efficiency of the different protocols.

Authors:  Justin M Zook; Erno Lindner
Journal:  Anal Chem       Date:  2009-07-01       Impact factor: 6.986

5.  Ion amperometry at the interface between two immiscible electrolyte solutions in view of realizing the amperometric ion-selective electrode.

Authors:  Zdenek Samec; Eva Samcová; Hubert H Girault
Journal:  Talanta       Date:  2004-05-10       Impact factor: 6.057

6.  Thin layer coulometry with ionophore based ion-selective membranes.

Authors:  Ewa Grygolowicz-Pawlak; Eric Bakker
Journal:  Anal Chem       Date:  2010-06-01       Impact factor: 6.986

7.  Voltammetric and amperometric transduction for solvent polymeric membrane ion sensors.

Authors:  S Jadhav; E Bakker
Journal:  Anal Chem       Date:  1999-09-01       Impact factor: 6.986

  7 in total