AIMS: This study aims to relate bone density in Hounsfield units (Hu) with the primary implant stability measured by insertion torque (Ncm) and resonance frequency analysis (ISQ).
MATERIALS AND METHODS: Ten patients were included in this study. A total of 54 implant sites were provided from 10 computerized tomography scans. The computerized tomography scan was used for the preoperative evaluation of bone density for each patient. The bone mean density around planned implants was determined with Physioplanet TM software. Bone quality according resistance to drilling, insertion torque and resonance frequency measurements were recorded.
RESULTS: A statistically significant relationship was observed between bone quality density and location with ISQ values.
CONCLUSIONS: This research demonstrates a strong relationship between the bone density values from computerized tomography and the location in the maxillaries. A correlation exists between bone quality, according to the Lekholm & Zarb classification, and Hu computerized tomography values. The primary implant stability measured with resonance frequency analysis depends on bone density values, bone quality and implant location.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 20711163     DOI: 10.4317/medoral.16.e62

Source DB:  PubMed          Journal:  Med Oral Patol Oral Cir Bucal        ISSN: 1698-4447


  9 in total

1.  Implant-supported fixed prostheses in a Patient with Osteogenesis Imperfecta: A 4-year follow-up.

Authors:  Mario Caicedo-Rubio; Elvira Ferrés-Amat; Eduard Ferrés-Padró
Journal:  J Clin Exp Dent       Date:  2017-12-01

2.  Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, Osseodensification: an in vitro study.

Authors:  J Barberá-Millán; C Larrazábal-Morón; J-J Enciso-Ripoll; E Pérez-Pevida; D Chávarri-Prado; M-D Gómez-Adrián
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2021-05-01

3.  Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading.

Authors:  Seong-Beom Kim; Pil-Young Yun; Sang-Yun Kim; Yang-Jin Yi; Ji-Yun Kim; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

4.  The influence of length of implant on primary stability: An in vitro study using resonance frequency analysis.

Authors:  Anwar B Bataineh; Ala M Al-Dakes
Journal:  J Clin Exp Dent       Date:  2017-01-01

5.  Predictability of bone density at posterior mandibular implant sites using cone-beam computed tomography intensity values.

Authors:  Mustafa Alkhader; Malik Hudieb; Yousef Khader
Journal:  Eur J Dent       Date:  2017 Jul-Sep

6.  The evaluation of implant stability measured by resonance frequency analysis in different bone types.

Authors:  Naser Sargolzaie; Sarah Samizade; Hamidreza Arab; Habibollah Ghanbari; Leila Khodadadifard; Amin Khajavi
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2019-02-26

Review 7.  Stability of Dental Implants and Thickness of Cortical Bone: Clinical Research and Future Perspectives. A Systematic Review.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Paolo Capparè; Silvia Barbon; Enrico Felice Gherlone
Journal:  Materials (Basel)       Date:  2021-11-25       Impact factor: 3.623

8.  Evaluation of Cortical Bone Thickness of Posterior Implant Sites Using CBCT in Iraqi Population.

Authors:  Nuhad A Hassan; Aseel S Khazaal Al-Jaboori; Afya Sahib Diab Al-Radha
Journal:  Int J Dent       Date:  2022-09-05

9.  Correlation between Primary, Secondary Stability, Bone Density, Percentage of Vital Bone Formation and Implant Size.

Authors:  Vasilena Ivanova; Ivan Chenchev; Stefan Zlatev; Eitan Mijiritsky
Journal:  Int J Environ Res Public Health       Date:  2021-06-30       Impact factor: 3.390

  9 in total