Literature DB >> 20711087

The safety and efficacy of passive removal of silicone oil with 23-gauge transconjunctival sutureless system.

Sourabh D Patwardhan1, Rajvardhan Azad, Vinit Shah, Yograj Sharma.   

Abstract

PURPOSE: To evaluate the safety and efficacy of passive removal of silicone oil with 23-gauge (G) transconjunctival sutureless system.
METHODS: This is a single-center, prospective, interventional, randomized control study. Forty eyes of 40 patients were enrolled in this study and randomized into 2 groups. Group 1 (n = 20) patients underwent passive removal of silicone oil with 23-G transconjunctival sutureless system. Group 2 (n = 20) underwent 20-G active silicone oil removal using all three 20-G ports. In both groups, air-fluid exchange was performed and the globe was left air filled at the end of surgery. All eyes in both groups received 360 degrees endolaser. We recorded surgical time, time for silicone oil removal, number of sutured 23-G sclerotomy sites, presence of preoperative scarring at sclerotomy site, postoperative hypotony, endophthalmitis, and inflammation at sclerotomy site.
RESULTS: Opening and closing times were significantly shorter in Group 1 than in Group 2. Only 3 cases (15%) in Group 1 required 1 additional suture each in the superior sclerotomy site. Both groups were similar in safety in terms of chance of endophthalmitis, redetachment rate, and postoperative hypotony. Only 1 patient of Group 1 (5%) and 5 patients of Group 2 (25%) showed significant conjunctival inflammation at the end of 2 weeks.
CONCLUSION: Passive removal of silicone oil with 23-G transconjunctival sutureless system may hasten postoperative recovery by decreasing overall surgical time and postoperative inflammation. It is a safe and effective procedure when compared with 20-G active silicone oil removal for 1000 centistoke oil.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20711087     DOI: 10.1097/IAE.0b013e3181dde612

Source DB:  PubMed          Journal:  Retina        ISSN: 0275-004X            Impact factor:   4.256


  7 in total

1.  Efficacy and safety of active silicone oil removal through a 23-gauge transconjunctival cannula using an external vacuum pump.

Authors:  Hyun Ju Oh; Woohyok Chang; Min Sagong
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

2.  Effect of fluid-air exchange on reducing residual silicone oil after silicone oil removal.

Authors:  Hideki Shiihara; Taiji Sakamoto; Hiroto Terasaki; Takehiro Yamashita; Naoya Yoshihara; Fumiki Okamoto; Nahoko Ogata; Toshifumi Yamashita; Shozo Sonoda; Yoshinori Mitamura
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-06-14       Impact factor: 3.117

3.  Trocar opening: silicone oil removal with phacoemulsification and intraocular lens implantation.

Authors:  Xu Zhang; Ya-Jie Pan; Zheng-Yu Song
Journal:  Int J Ophthalmol       Date:  2019-11-18       Impact factor: 1.779

4.  Clinical presentation of a mixed 23-gauge infusion and 20-gauge pars plana technique for active silicone oil removal.

Authors:  Jian-Qin Lei; An-Ming Xie; Qiang Shi
Journal:  Int J Ophthalmol       Date:  2012-10-18       Impact factor: 1.779

5.  Active Silicone Oil Removal with a Transconjunctival Sutureless System: Is the 23-Gauge System Safe and Effective?

Authors:  Mahmut Kaya; Ayhan Özyurt; Arif Taylan Öztürk; Duygu Er; Süleyman Kaynak; Nilüfer Koçak
Journal:  Turk J Ophthalmol       Date:  2016-01-05

6.  Small gauge vitrectomy: Recent update.

Authors:  Sumeet Khanduja; Ashish Kakkar; Saptrishi Majumdar; Rajpal Vohra; Satpal Garg
Journal:  Oman J Ophthalmol       Date:  2013-01

7.  Passive removal of silicone oil through 23 gauge transconjunctival sutureless vitrectomy system.

Authors:  Nisar Ahmed Siyal; Lakhani Das Hargun; Shahid Wahab
Journal:  Pak J Med Sci       Date:  2016 May-Jun       Impact factor: 1.088

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.