Literature DB >> 20709520

An electrochemical immunosensor for testosterone using functionalized magnetic beads and screen-printed carbon electrodes.

Marcos Eguílaz1, María Moreno-Guzmán, Susana Campuzano, Araceli González-Cortés, Paloma Yáñez-Sedeño, José M Pingarrón.   

Abstract

A disposable electrochemical immunosensor using screen-printed carbon electrodes (SPCEs) and protein A-functionalized magnetic beads (MBs) was developed for the determination of testosterone. Anti-testosterone was immobilized onto MBs and a direct competitive immunoassay involving testosterone labeled with peroxidase (HRP) was performed. The resulting conjugate was trapped on the SPCE with a small magnet. Testosterone determination was carried out by amperometry at -0.2V upon H2O2 additions using hydroquinone (HQ) as the redox mediator. The experimental variables involved in the immunosensor response to testosterone were evaluated. Under the optimized conditions, a calibration plot for testosterone was obtained with a linear range between 5.0×10(-3) and 50 ng/mL (r=0.995). The detection limit was 1.7 pg/mL and the EC50 was 0.25±0.04 ng/mL. These characteristics are notably better than those achieved with other reported immunosensors. Furthermore, anti-testosterone/MBs conjugates were shown to be stable for at least 25 days. A good selectivity was also found against other steroid hormones. The usefulness of the immunosensor was demonstrated by analyzing human serum spiked with 1 and 10 ng/mL testosterone.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20709520     DOI: 10.1016/j.bios.2010.07.060

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  9 in total

1.  Amperometric immunoassay for the obesity biomarker amylin using a screen printed carbon electrode functionalized with an electropolymerized carboxylated polypyrrole.

Authors:  Gonzalo Martínez-García; Esther Sánchez-Tirado; Araceli González-Cortés; Paloma Yáñez-Sedeño; José M Pingarrón
Journal:  Mikrochim Acta       Date:  2018-06-09       Impact factor: 5.833

Review 2.  Combining electrochemical sensors with miniaturized sample preparation for rapid detection in clinical samples.

Authors:  Natinan Bunyakul; Antje J Baeumner
Journal:  Sensors (Basel)       Date:  2014-12-30       Impact factor: 3.576

Review 3.  Electrochemical (Bio)Sensors for Pesticides Detection Using Screen-Printed Electrodes.

Authors:  Beatriz Pérez-Fernández; Agustín Costa-García; Alfredo de la Escosura- Muñiz
Journal:  Biosensors (Basel)       Date:  2020-04-02

Review 4.  Advances in the Determination of Anabolic-Androgenic Steroids: From Standard Practices to Tailor-Designed Multidisciplinary Approaches.

Authors:  Lukáš Huml; Jan Tauchen; Silvie Rimpelová; Barbora Holubová; Oldřich Lapčík; Michal Jurášek
Journal:  Sensors (Basel)       Date:  2021-12-21       Impact factor: 3.576

5.  Binary MoS2 nanostructures as nanocarriers for amplification in multiplexed electrochemical immunosensing: simultaneous determination of B cell activation factor and proliferation-induced signal immunity-related cytokines.

Authors:  Beatriz Arévalo; Marina Blázquez-García; Alejandro Valverde; Verónica Serafín; Ana Montero-Calle; Guillermo Solís-Fernández; Rodrigo Barderas; Susana Campuzano; Paloma Yáñez-Sedeño; José M Pingarrón
Journal:  Mikrochim Acta       Date:  2022-03-14       Impact factor: 6.408

6.  Towards Control and Oversight of SARS-CoV-2 Diagnosis and Monitoring through Multiplexed Quantitative Electroanalytical Immune Response Biosensors.

Authors:  Rebeca M Torrente-Rodríguez; Ana Montero-Calle; Clara San Bartolomé; Olga Cano; Mónica Vázquez; María Iglesias-Caballero; Andrés Corral-Lugo; Michael J McConnell; Mariona Pascal; Vicente Mas; José M Pingarrón; Rodrigo Barderas; Susana Campuzano
Journal:  Angew Chem Int Ed Engl       Date:  2022-05-24       Impact factor: 16.823

7.  Towards Control and Oversight of SARS-CoV-2 Diagnosis and Monitoring through Multiplexed Quantitative Electroanalytical Immune Response Biosensors.

Authors:  Rebeca M Torrente-Rodríguez; Ana Montero-Calle; Clara San Bartolomé; Olga Cano; Mónica Vázquez; María Iglesias-Caballero; Andrés Corral-Lugo; Michael J McConnell; Mariona Pascal; Vicente Mas; José M Pingarrón; Rodrigo Barderas; Susana Campuzano
Journal:  Angew Chem Weinheim Bergstr Ger       Date:  2022-05-24

8.  Development of an Electrochemical CCL5 Chemokine Immunoplatform for Rapid Diagnosis of Multiple Sclerosis.

Authors:  Sara Guerrero; Esther Sánchez-Tirado; Lourdes Agüí; Araceli González-Cortés; Paloma Yáñez-Sedeño; José M Pingarrón
Journal:  Biosensors (Basel)       Date:  2022-08-07

Review 9.  Magnetic Particles Coupled to Disposable Screen Printed Transducers for Electrochemical Biosensing.

Authors:  Paloma Yáñez-Sedeño; Susana Campuzano; José M Pingarrón
Journal:  Sensors (Basel)       Date:  2016-09-25       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.