Literature DB >> 20706359

Fourteen-decade photocurrent measurements with large-area silicon photodiodes at room temperature.

G Eppeldauer, J E Hardis.   

Abstract

Recent improvements in commercial silicon photodiodes and operational amplifiers permit electrical noise to be reduced to an equivalent of 0.1 fA of photocurrent when a measurement time of 400 s is used. This is equivalent to a photocurrent resulting from fewer than 800 photons/s, and it implies a dynamic range of 14 orders of magnitude for a detector circuit. We explain the circuit theory, paying particular attention to the measurement bandwidth, the causes of noise and drift, and the proper selection of circuit components. These optical radiation detectors complement the primary radiometric standards. These detectors may replace photomultiplier tubes that have been used traditionally and or that were too costly to be used.

Entities:  

Year:  1991        PMID: 20706359     DOI: 10.1364/AO.30.003091

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  9 in total

1.  Eliminating the middleman: ultraviolet scale realization using a laser-driven plasma light source.

Authors:  Uwe Arp; Edward Hagley; Robert Vest
Journal:  Appl Opt       Date:  2021-02-20       Impact factor: 1.980

2.  Opto-Mechanical and Electronic Design of a Tunnel-Trap Si Radiometer.

Authors:  G P Eppeldauer; D C Lynch
Journal:  J Res Natl Inst Stand Technol       Date:  2000-12-01

3.  Calibration of High Heat Flux Sensors at NIST.

Authors:  A V Murthy; B K Tsai; C E Gibson
Journal:  J Res Natl Inst Stand Technol       Date:  1997 Jul-Aug

4.  Noise-Optimized Silicon Radiometers.

Authors:  G P Eppeldauer
Journal:  J Res Natl Inst Stand Technol       Date:  2000-04-01

5.  Chopped Radiation Measurements With Large Area Si Photodiodes.

Authors:  George Eppeldauer
Journal:  J Res Natl Inst Stand Technol       Date:  1998-04-01

6.  Development of a Bolometer Detector System for the NIST High Accuracy Infrared Spectrophotometer.

Authors:  Y Zong; R U Datla
Journal:  J Res Natl Inst Stand Technol       Date:  1998-12-01

7.  The NIST High Accuracy Scale for Absolute Spectral Response from 406 nm to 920 nm.

Authors:  T C Larason; S S Bruce; C L Cromer
Journal:  J Res Natl Inst Stand Technol       Date:  1996 Mar-Apr

8.  The NIST Detector-Based Luminous Intensity Scale.

Authors:  C L Cromer; G Eppeldauer; J E Hardis; T C Larason; Y Ohno; A C Parr
Journal:  J Res Natl Inst Stand Technol       Date:  1996 Mar-Apr

9.  The Candela and Photometric and Radiometric Measurements.

Authors:  A C Parr
Journal:  J Res Natl Inst Stand Technol       Date:  2001-02-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.