Literature DB >> 20705252

Effect of low-flow anesthesia education on knowledge, attitude and behavior of the anesthesia team.

Volkan Hanci1, Serhan Yurtlu, Hilal Ayoğlu, Rahşan Dilek Okyay, Gülay Erdoğan, Mustafa Abduşoğlu, Esin Sayin, Işil Ozkoçak Turan.   

Abstract

The aim of this study was to evaluate the effect of education on the knowledge, attitude and behavior of anesthesiology staff and residents towards low-flow anesthesia. The staff and residents in the Department of Anesthesia and Reanimation, Zonguldak Karaelmas University were given theoretical and practical training in delivering low-flow anesthesia. To evaluate their attitudes and behaviors toward low-flow anesthesia, we collected data during the 6 months before training, during the first 3 months after training, and at 4-6 months after training. Anesthesia follow-up records, operation time, volatile anesthetic agent used, and the amount (in liters) of fresh gas low mid-anesthesia were recorded in all three stages. A total of 3,158 patients received general anesthesia and inhalation anesthesia was used in 3,115 of these patients. Our study group consisted of 2,752 patients who had no absolute or relative contraindications to low-flow anesthesia. While the mean fresh gas flow was 4.00 +/- 0.00 L/min before training, this level dropped to 2.98 L/min in the first 3 months after training, and to 3.26 L/min in the following 3 months. The mean fresh gas flow was significantly lower at the two post-training assessments than before training (p < 0.05). In conclusion, low-flow anesthesia may be used more frequently if educational seminars are provided to anesthetists. The use of low-flow anesthesia may increase further by allocating more time to this technique in anesthesia training programs provided at regular intervals. Copyright 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20705252     DOI: 10.1016/S1607-551X(10)70067-X

Source DB:  PubMed          Journal:  Kaohsiung J Med Sci        ISSN: 1607-551X            Impact factor:   2.744


  3 in total

1.  An observation from an online survey: is fresh gas flow used for sevoflurane and desflurane different from isoflurane based anesthesia?

Authors:  Habib Md Reazaul Karim; Mamta Sinha; Mayank Kumar; Monica Khetrapal; Rashmi Dubey
Journal:  Med Gas Res       Date:  2019 Jan-Mar

2.  Analyzing Volatile Anesthetic Consumption by Auditing Fresh Gas Flow: An Observational Study at an Academic Hospital.

Authors:  Luis Tollinche; KaySee Tan; Austin Han; Leslie Ojea; Cindy Yeoh
Journal:  Int J Anesth Anesth       Date:  2018-04-26

3.  Practice Pattern of Fresh Gas Flow and Volatile Agent Choices among Anesthesiologists Working in Different Indian Hospitals: An Online Survey.

Authors:  Mayank Kumar; Mamta Sinha; Habib Md Reazaul Karim; Chinmaya Kumar Panda; Subrata Kumar Singha
Journal:  Anesth Essays Res       Date:  2018 Oct-Dec
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.