Literature DB >> 20703654

Field programmable gate array based fuzzy neural signal processing system for differential diagnosis of QRS complex tachycardia and tachyarrhythmia in noisy ECG signals.

Shubhajit Roy Chowdhury1.   

Abstract

The paper reports of a Field Programmable Gate Array (FPGA) based embedded system for detection of QRS complex in a noisy electrocardiogram (ECG) signal and thereafter differential diagnosis of tachycardia and tachyarrhythmia. The QRS complex has been detected after application of entropy measure of fuzziness to build a detection function of ECG signal, which has been previously filtered to remove power line interference and base line wander. Using the detected QRS complexes, differential diagnosis of tachycardia and tachyarrhythmia has been performed. The entire algorithm has been realized in hardware on an FPGA. Using the standard CSE ECG database, the algorithm performed highly effectively. The performance of the algorithm in respect of QRS detection with sensitivity (Se) of 99.74% and accuracy of 99.5% is achieved when tested using single channel ECG with entropy criteria. The performance of the QRS detection system has been compared and found to be better than most of the QRS detection systems available in literature. Using the system, 200 patients have been diagnosed with an accuracy of 98.5%.

Entities:  

Mesh:

Year:  2010        PMID: 20703654     DOI: 10.1007/s10916-010-9543-7

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  12 in total

1.  The use of the Hilbert transform in ECG signal analysis.

Authors:  D Benitez; P A Gaydecki; A Zaidi; A P Fitzpatrick
Journal:  Comput Biol Med       Date:  2001-09       Impact factor: 4.589

Review 2.  Electrophysiology: Ventricular tachycardia: diagnosis of broad QRS complex tachycardia.

Authors:  H J Wellens
Journal:  Heart       Date:  2001-11       Impact factor: 5.994

3.  Transductive reliability estimation for medical diagnosis.

Authors:  Matjaz Kukar
Journal:  Artif Intell Med       Date:  2003 Sep-Oct       Impact factor: 5.326

4.  A real-time QRS detection method based on moving-averaging incorporating with wavelet denoising.

Authors:  Szi-Wen Chen; Hsiao-Chen Chen; Hsiao-Lung Chan
Journal:  Comput Methods Programs Biomed       Date:  2006-05-22       Impact factor: 5.428

5.  Comparative study of morphological and time-frequency ECG descriptors for heartbeat classification.

Authors:  Ivaylo Christov; Gèrman Gómez-Herrero; Vessela Krasteva; Irena Jekova; Atanas Gotchev; Karen Egiazarian
Journal:  Med Eng Phys       Date:  2006-02-14       Impact factor: 2.242

6.  A digital filter for the QRS complex detection.

Authors:  M Okada
Journal:  IEEE Trans Biomed Eng       Date:  1979-12       Impact factor: 4.538

7.  A real-time QRS detection algorithm.

Authors:  J Pan; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1985-03       Impact factor: 4.538

8.  A learning filter for removing noise interference.

Authors:  G S Furno; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1983-04       Impact factor: 4.538

9.  Removal of base-line wander and power-line interference from the ECG by an efficient FIR filter with a reduced number of taps.

Authors:  J A Van Alsté; T S Schilder
Journal:  IEEE Trans Biomed Eng       Date:  1985-12       Impact factor: 4.538

10.  QRS wave detection.

Authors:  J Fraden; M R Neuman
Journal:  Med Biol Eng Comput       Date:  1980-03       Impact factor: 2.602

View more
  1 in total

1.  FPGA Implementation of Heart Rate Monitoring System.

Authors:  D Panigrahy; M Rakshit; P K Sahu
Journal:  J Med Syst       Date:  2015-12-07       Impact factor: 4.460

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.