Does modifying electrode placement of the 12 lead ECG matter in healthy subjects?

James P Sheppard1, Thomas A Barker, Aaron M Ranasinghe, Thomas H Clutton-Brock, Michael P Frenneaux, Michael J Parkes.   

Abstract

BACKGROUND: Limb electrodes for the 12 lead ECG are routinely placed on the torso during exercise stress testing or when limbs are clinically inaccessible. It is unclear whether such electrode modification produces ECG changes in healthy male or female subjects that are clinically important according to the 2009 AHA, ACCF, HRS guidelines. We therefore measured whether ECG modification produced clinically important or false positive ECG changes e.g., appearance of Q waves in leads V(1-3), ST changes greater than 0.1 mV, T wave changes greater than 0.5 mV (frontal plane) or 1 mV (transverse plane), QRS axis shifts or alterations to QTc/P-R/QRS intervals.
METHODS: The 12 lead ECG was measured in 18 healthy and semi-recumbent subjects using the standard and Takuma modified limb placements.
RESULTS: In the frontal plane we demonstrate that the modification of limb electrode placement produces small Q, R and T wave amplitude and QRS axis changes that are statistically but not clinically significant. In the transverse plane it produces no statistically or clinically significant changes in the ECG or in ST segment morphology, P-R, QRS or QTc intervals.
CONCLUSIONS: We provide better and more robust evidence that routine modification of limb electrode placement produces only minor changes to the ECG waveform in healthy subjects. These are not clinically significant according to the 2009 guidelines and thus have no effect on the clinical specificity of the 12 lead ECG.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20701990     DOI: 10.1016/j.ijcard.2010.07.013

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  6 in total

1.  Modified precordial lead ECG SafOne on electrocardiography recordings.

Authors:  Wan Nishfa Dewi; Safri Safri; Iswadi Hasyim Rosma
Journal:  Sci Rep       Date:  2022-05-13       Impact factor: 4.996

2.  Modified limb lead system: Its effects on wave amplitudes and axis in surface ECG.

Authors:  Vimal Prabhu Pandiyan
Journal:  Anatol J Cardiol       Date:  2017-01       Impact factor: 1.596

3.  Hypocapnia Alone Fails to Provoke Important Electrocardiogram Changes in Coronary Artery Diseased Patients.

Authors:  Michael J Parkes; James P Sheppard; Thomas Barker; Aaron M Ranasinghe; Eshan Senanayake; Thomas H Clutton-Brock; Michael P Frenneaux
Journal:  Front Physiol       Date:  2020-01-20       Impact factor: 4.566

4.  True unipolar ECG machine for Wilson Central Terminal measurements.

Authors:  Gaetano D Gargiulo
Journal:  Biomed Res Int       Date:  2015-10-01       Impact factor: 3.411

5.  Normal limits of ECG measurements related to atrial activity using a modified limb lead system.

Authors:  Jayaraman Sivaraman; Gandhi Uma; Sangareddi Venkatesan; Mangalanathan Umapathy; Vella Elumalai Dhandapani
Journal:  Anatol J Cardiol       Date:  2014-02-26       Impact factor: 1.596

6.  Modified limb lead ECG system effects on electrocardiographic wave amplitudes and frontal plane axis in sinus rhythm subjects.

Authors:  Sivaraman Jayaraman; Venkatesan Sangareddi; R Periyasamy; Justin Joseph; Ravi Marimuthu Shanmugam
Journal:  Anatol J Cardiol       Date:  2016-06-29       Impact factor: 1.596

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.