Literature DB >> 20701620

Early loading of single crowns supported by 6-mm-long implants with a moderately rough surface: a prospective 2-year follow-up cohort study.

Fabio Rossi1, Emanuele Ricci, Claudio Marchetti, Niklaus P Lang, Daniele Botticelli.   

Abstract

AIM: To evaluate prospectively the clinical and radiographic outcomes after 2 years of loading of 6 mm long moderately rough implants supporting single crowns in the posterior regions.
MATERIAL AND METHODS: Forty SLActive Straumann short (6 mm) implants were placed in 35 consecutively treated patients. Nineteen implants, 4.1 mm in diameter, and 21 implants, 4.8 mm in diameter, were installed. Implants were loaded after 6 weeks of healing. Implant survival rate, marginal bone loss and resonance frequency analysis (RFA) were evaluated at different intervals. The clinical crown/implant ratio was also calculated.
RESULTS: Two out of 40 implants were lost before loading. Hence, the survival rate before loading was 95%. No further technical or biological complications were encountered during the 2-year follow-up. The mean marginal bone loss before loading was 0.34+/-0.38 mm. After loading, the mean marginal bone loss was 0.23+/-0.33 and 0.21+/-0.39 mm at the 1- and 2-year follow-ups. The RFA values increased between insertion (70.2+/-9) and the 6-week evaluation (74.8+/-6.1). The clinical crown/implant ratio increased with time from 1.5 at the delivery of the prosthesis to 1.8 after 2 years of loading.
CONCLUSION: Short implants (6 mm) with a moderately rough surface loaded early (after 6 weeks) during healing yielded high implant survival rates and moderate loss of bone after 2 years of loading. Longer observation periods are needed to draw more definite conclusions on the reliability of short implants supporting single crowns.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20701620     DOI: 10.1111/j.1600-0501.2010.01942.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  12 in total

1.  Short implants in partially edentuolous maxillae and mandibles: a 10 to 20 years retrospective evaluation.

Authors:  Diego Lops; Eriberto Bressan; Gianluca Pisoni; Niccolò Cea; Boris Corazza; Eugenio Romeo
Journal:  Int J Dent       Date:  2012-07-09

2.  Survival rate of short, locking taper implants with a plateau design: a 5-year retrospective study.

Authors:  Kemal Özgür Demiralp; Nihat Akbulut; Sebnem Kursun; Didem Argun; Nilsun Bagis; Kaan Orhan
Journal:  Biomed Res Int       Date:  2015-04-16       Impact factor: 3.411

3.  Reality of dental implant surface modification: a short literature review.

Authors:  In-Sung Yeo
Journal:  Open Biomed Eng J       Date:  2014-10-31

4.  Comparative Study of the Early Loading of Resorbable Blasting Media and Sandblasting with Large-grit and Acid-etching Surface Implants: A Retrospective Cohort Study.

Authors:  Sung-Beom Kim; Young-Kyun Kim; Su-Gwan Kim; Ji-Su Oh; Byung-Hoon Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2014-11-12

5.  A randomized, 12-month controlled trial to evaluate non-inferiority of early compared to conventional loading of modSLA implants in single tooth gaps.

Authors:  Michel Dard; Makoto Shiota; Minoru Sanda; Yasutomo Yajima; Hideshi Sekine; Shohei Kasugai
Journal:  Int J Implant Dent       Date:  2016-04-04

6.  Prospective, Clinical Pilot Study with Eleven 4-Mm Extra-Short Implants Splinted to Longer Implants for Posterior Maxilla Rehabilitation.

Authors:  Daniel Torassa; Pablo Naldini; José Luis Calvo-Guirado; Enrique Fernández-Bodereau
Journal:  J Clin Med       Date:  2020-01-28       Impact factor: 4.241

7.  A meta-analysis indicating extra-short implants (≤ 6 mm) as an alternative to longer implants (≥ 8 mm) with bone augmentation.

Authors:  Xiaoran Yu; Ruogu Xu; Zhengchuan Zhang; Yang Yang; Feilong Deng
Journal:  Sci Rep       Date:  2021-04-14       Impact factor: 4.379

8.  Biomechanics and load resistance of short dental implants: a review of the literature.

Authors:  Istabrak Hasan; Christoph Bourauel; Torsten Mundt; Friedhelm Heinemann
Journal:  ISRN Dent       Date:  2013-05-08

9.  Current knowledge about the hydrophilic and nanostructured SLActive surface.

Authors:  Ann Wennerberg; Silvia Galli; Tomas Albrektsson
Journal:  Clin Cosmet Investig Dent       Date:  2011-09-05

10.  Greater Osseointegration Potential with Nanostructured Surfaces on TiZr: Accelerated vs. Real-Time Ageing.

Authors:  Andreas Stavropoulos; Rebecca Sandgren; Benjamin Bellon; Anton Sculean; Benjamin E Pippenger
Journal:  Materials (Basel)       Date:  2021-03-29       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.