Literature DB >> 20699332

Comparative parallel assessment of a transfer device in reducing 5-fluorouracil environmental contamination inside positive air pressure isolators.

Fabien Forges1, Xavier Simoens, Franck Chauvin.   

Abstract

The environmental contamination of the antineoplastic drugs circuit, due to the centralization of preparation and the increased number of the patients treated, brought about a new occupational hazard: the chronic exposure to low doses of antineoplastic drugs. The rationalization of the hospital budgets imposes a meticulous assessment of the devices available for the preparation, in order to justify their interest, even their cost. A prospective comparative study with parallel arms was led inside the Pharmacy of the Institut de Cancerologie de la Loire in order to evaluate the Spike Swan®, a transfer device. The aim was to assess the Spike Swan® effectiveness. The antineoplastic drugs environmental contamination within the isolators is considered as a potential starting point for a larger dissemination of cytotoxic products. Therefore, the primary endpoint was the surface contamination level with 5-fluorouracil and the comparator was the standard preparation technique using needles and aeration needles. This study did not show significant effectiveness for the Spike Swan® in reducing surface contamination. Nevertheless, this device could be used to prepare large volumes and to secure occasional handlers, because it is easy to handle.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20699332     DOI: 10.1177/1078155210380291

Source DB:  PubMed          Journal:  J Oncol Pharm Pract        ISSN: 1078-1552            Impact factor:   1.809


  4 in total

1.  Reduction in Surface Contamination With Cyclophosphamide in 30 US Hospital Pharmacies Following Implementation of a Closed-System Drug Transfer Device.

Authors:  Paul J M Sessink; Jason Trahan; Joseph W Coyne
Journal:  Hosp Pharm       Date:  2013-03

Review 2.  Identification of Knowledge Gaps Regarding Healthcare Workers' Exposure to Antineoplastic Drugs: Review of Literature, North America versus Europe.

Authors:  Chun-Yip Hon; Cris Barzan; George Astrakianakis
Journal:  Saf Health Work       Date:  2014-06-11

3.  Effectiveness of a Closed-System Transfer Device in Reducing Surface Contamination in a New Antineoplastic Drug-Compounding Unit: A Prospective, Controlled, Parallel Study.

Authors:  Nicolas Simon; Michèle Vasseur; Marine Pinturaud; Marion Soichot; Camille Richeval; Luc Humbert; Michèle Lebecque; Ousseini Sidikou; Christine Barthelemy; Pascal Bonnabry; Delphine Allorge; Bertrand Décaudin; Pascal Odou
Journal:  PLoS One       Date:  2016-07-08       Impact factor: 3.240

Review 4.  Closed-system drug-transfer devices plus safe handling of hazardous drugs versus safe handling alone for reducing exposure to infusional hazardous drugs in healthcare staff.

Authors:  Kurinchi Selvan Gurusamy; Lawrence Mj Best; Cynthia Tanguay; Elaine Lennan; Mika Korva; Jean-François Bussières
Journal:  Cochrane Database Syst Rev       Date:  2018-03-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.