Literature DB >> 20698581

Study of Discontinuous Atmospheric Pressure Interfaces for Mass Spectrometry Instrumentation Development.

Wei Xu1, Nicholas Charipar, Matthew A Kirleis, Yu Xia, Zheng Ouyang.   

Abstract

The discontinuous atmospheric pressure interface (DAPI) has allowed the transfer of ions from atmospheric pressure ionization sources to an ion trap mass analyzer in hand-held mass spectrometers with miniature pumping systems at transfer efficiencies high enough for proper chemical analysis. The DAPI potentially would allow a significant enhancement to the mass analysis efficiency of laboratory-scale mass spectrometers, which have pumping systems of much larger capacities. A laboratory-scale mass spectrometer with a DAPI-RIT (rectilinear ion trap)-DAPI configuration has been developed to explore this possibility. The gas dynamic effects on ion trapping and mass analysis have been studied at various conditions. A pulsed nanoelectrospray ionization source synchronized with the DAPI has been implemented to improve the sample usage efficiency as well as to adjust the number of ions to be trapped for MS analysis, so that space charge effects can be avoided. Single-scan spectra of peptides were recorded with an ionization time as short as 1 mus, corresponding to an analyte consumption of several attomoles. The simplicity of application of the DAPI for performing ion/molecule and ion/ion reactions has also been demonstrated with proton transfer and electron transfer dissociation reactions with peptides.

Entities:  

Year:  2010        PMID: 20698581     DOI: 10.1021/ac101002t

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Simulation of rarefied gas flows in atmospheric pressure interfaces for mass spectrometry systems.

Authors:  Sandilya Garimella; Xiaoyu Zhou; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2013-09-17       Impact factor: 3.109

2.  Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet.

Authors:  Xinqiong Lu; Quan Yu; Qian Zhang; Kai Ni; Xiang Qian; Fei Tang; Xiaohao Wang
Journal:  J Am Soc Mass Spectrom       Date:  2017-04-21       Impact factor: 3.109

3.  Accelerated simulation study of space charge effects in quadrupole ion traps using GPU techniques.

Authors:  Xingchuang Xiong; Wei Xu; Xiang Fang; Yulin Deng; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2012-08-09       Impact factor: 3.109

4.  Direct identification of prohibited substances in cosmetics and foodstuffs using ambient ionization on a miniature mass spectrometry system.

Authors:  Qiang Ma; Hua Bai; Wentao Li; Chao Wang; Xinshi Li; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chim Acta       Date:  2016-01-27       Impact factor: 6.558

5.  Characterization of a DAPI-RIT-DAPI system for gas-phase ion/molecule and ion/ion reactions.

Authors:  Ziqing Lin; Lei Tan; Sandilya Garimella; Linfan Li; Tsung-Chi Chen; Wei Xu; Yu Xia; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2013-10-23       Impact factor: 3.109

6.  Analysis of polycyclic aromatic hydrocarbons using desorption atmospheric pressure chemical ionization coupled to a portable mass spectrometer.

Authors:  Fred P M Jjunju; Simon Maher; Anyin Li; Abraham K Badu-Tawiah; Stephen Taylor; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2014-12-13       Impact factor: 3.109

7.  Ion sponge: a 3-dimentional array of quadrupole ion traps for trapping and mass-selectively processing ions in gas phase.

Authors:  Wei Xu; Linfan Li; Xiaoyu Zhou; Zheng Ouyang
Journal:  Anal Chem       Date:  2014-04-28       Impact factor: 6.986

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.