Literature DB >> 2069829

Osseointegration and the edentulous predicament. The 10-year-old Toronto study.

G A Zarb1, A Schmitt.   

Abstract

This prospective study at the University of Toronto reports the 5-10-year results of treatment of edentulous patients with osseointegrated implant supported bridges. It comprised 46 consecutively treated patients, chosen because optimisation of traditional prostheses was not successful and because they were in sufficiently good health to allow minor out-patient surgery. Two hundred and seventy-four implants were surgically placed in 49 arches (three patients were treated in both arches) between October 1979 and March 1984. At the end of the 5-10-year observation period, 242 (88.32%) of the implants remained osseointegrated and 233 or 85.04% of these implants were used to support 43 fixed bridges and five overdentures. Nine implants, though osseointegrated, were not exposed and were not used to support the prostheses. Forty-eight of the 49 arches continue to be successfully restored with implant retained prostheses.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2069829     DOI: 10.1038/sj.bdj.4807583

Source DB:  PubMed          Journal:  Br Dent J        ISSN: 0007-0610            Impact factor:   1.626


  7 in total

1.  In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits.

Authors:  Thallita Pereira Queiroz; Rafael Scaf de Molon; Francisley Ávila Souza; Rogério Margonar; Anahi Herrera Aparecida Thomazini; Antônio Carlos Guastaldi; Eduardo Hochuli-Vieira
Journal:  Clin Oral Investig       Date:  2016-08-16       Impact factor: 3.573

2.  A comparative study on the accuracy of the devices for measuring the implant stability.

Authors:  In-Ho Cho; Young-Il Lee; Young-Mi Kim
Journal:  J Adv Prosthodont       Date:  2009-11-30       Impact factor: 1.904

3.  Morphometric analysis of maxillary alveolar regions for immediate implantation.

Authors:  Man-Soo Park; Young-Bum Park; Hyunmin Choi; Hong-Seok Moon; Moon-Kyu Chung; In-Ho Cha; Hee-Jin Kim; Dong-Hoo Han
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

4.  Reality of dental implant surface modification: a short literature review.

Authors:  In-Sung Yeo
Journal:  Open Biomed Eng J       Date:  2014-10-31

5.  Enhanced Osseointegration of a Modified Titanium Implant with Bound Phospho-Threonine: A Preliminary In Vivo Study.

Authors:  Yohei Okazaki; Kazuya Doi; Yoshifumi Oki; Reiko Kobatake; Yasuhiko Abe; Kazuhiro Tsuga
Journal:  J Funct Biomater       Date:  2017-05-25

6.  Effects of continual intermittent administration of parathyroid hormone on implant stability in the presence of osteoporosis: an in vivo study using resonance frequency analysis in a rabbit model.

Authors:  Yoshifumi Oki; Kazuya Doi; Yusuke Makihara; Reiko Kobatake; Takayasu Kubo; Kazuhiro Tsuga
Journal:  J Appl Oral Sci       Date:  2017 Sep-Oct       Impact factor: 2.698

7.  Development of implant/interconnected porous hydroxyapatite complex as new concept graft material.

Authors:  Kazuya Doi; Hiroshi Oue; Koji Morita; Shiho Kajihara; Takayasu Kubo; Katsunori Koretake; Vittoria Perrotti; Giovanna Iezzi; Adriano Piattelli; Yasumasa Akagawa
Journal:  PLoS One       Date:  2012-11-09       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.