Literature DB >> 20697459

Multicomponent Breath Analysis With Infrared Absorption Using Room-Temperature Quantum Cascade Lasers.

Joanne H Shorter1, David D Nelson, J Barry McManus, Mark S Zahniser, Donald K Milton.   

Abstract

Breath analysis is a powerful noninvasive technique for the diagnosis and monitoring of respiratory diseases, including asthma and chronic obstructive pulmonary disease (COPD). Nitric oxide (NO) and carbon monoxide (CO) are markers of airway inflammation and can indicate the extent of respiratory diseases. We have developed a compact fast response laser system for analysis of multiple gases by infrared absorption. The instrument uses room temperature quantum cascade lasers to simultaneously measure NO, CO, carbon dioxide (CO(2)) and nitrous oxide (N(2)O) in exhaled breath. Four breath flow rates are employed to explore their exchange dynamics in the lungs and airways. We obtain 1-s detection precisions of 0.5-0.8 parts-per-billion (ppb) for NO, CO, and N(2)O with an instrument response time of less than 1 s. The breath analysis system has been demonstrated in a preliminary study of volunteers. It is currently deployed in a trial clinical study.

Entities:  

Year:  2009        PMID: 20697459      PMCID: PMC2917122          DOI: 10.1109/JSEN.2009.2035764

Source DB:  PubMed          Journal:  IEEE Sens J        ISSN: 1530-437X            Impact factor:   3.301


  31 in total

1.  Elevation of exhaled ethane concentration in asthma.

Authors:  P Paredi; S A Kharitonov; P J Barnes
Journal:  Am J Respir Crit Care Med       Date:  2000-10       Impact factor: 21.405

2.  Methods for measuring ethane and pentane in expired air from rats and humans.

Authors:  M D Knutson; G J Handelman; F E Viteri
Journal:  Free Radic Biol Med       Date:  2000-02-15       Impact factor: 7.376

3.  Increase in exhaled carbon monoxide during exacerbations of cystic fibrosis.

Authors:  J D Antuni; S A Kharitonov; D Hughes; M E Hodson; P J Barnes
Journal:  Thorax       Date:  2000-02       Impact factor: 9.139

4.  A new and more accurate technique to characterize airway nitric oxide using different breath-hold times.

Authors:  Hye-Won Shin; Peter Condorelli; Steven C George
Journal:  J Appl Physiol (1985)       Date:  2004-12-23

Review 5.  Analysis of expired air for oxidation products.

Authors:  Paolo Paredi; Sergei A Kharitonov; Peter J Barnes
Journal:  Am J Respir Crit Care Med       Date:  2002-12-15       Impact factor: 21.405

6.  Breath sulfides and pulmonary function in cystic fibrosis.

Authors:  M A Kamboures; D R Blake; D M Cooper; R L Newcomb; M Barker; J K Larson; S Meinardi; E Nussbaum; F S Rowland
Journal:  Proc Natl Acad Sci U S A       Date:  2005-10-24       Impact factor: 11.205

7.  Increased carbon monoxide in exhaled air of asthmatic patients.

Authors:  K Zayasu; K Sekizawa; S Okinaga; M Yamaya; T Ohrui; H Sasaki
Journal:  Am J Respir Crit Care Med       Date:  1997-10       Impact factor: 21.405

8.  Infrared laser spectroscopy for online recording of exhaled carbon monoxide-a progress report.

Authors:  Thomas Fritsch; Peter Hering; Manfred Mürtz
Journal:  J Breath Res       Date:  2007-07-11       Impact factor: 3.262

9.  Exhaled nitric oxide in children with asthma receiving Xolair (omalizumab), a monoclonal anti-immunoglobulin E antibody.

Authors:  Philip E Silkoff; Francisco A Romero; Niroo Gupta; Robert G Townley; Henry Milgrom
Journal:  Pediatrics       Date:  2004-04       Impact factor: 7.124

10.  Exhaled nitric oxide as a diagnostic test for asthma: online versus offline techniques and effect of flow rate.

Authors:  Aaron Deykin; Anthony F Massaro; Jeffrey M Drazen; Elliot Israel
Journal:  Am J Respir Crit Care Med       Date:  2002-06-15       Impact factor: 21.405

View more
  4 in total

1.  Clinical study of multiple breath biomarkers of asthma and COPD (NO, CO(2), CO and N(2)O) by infrared laser spectroscopy.

Authors:  Joanne H Shorter; David D Nelson; J Barry McManus; Mark S Zahniser; Susan R Sama; Donald K Milton
Journal:  J Breath Res       Date:  2011-07-15       Impact factor: 3.262

Review 2.  Carbon monoxide in exhaled breath testing and therapeutics.

Authors:  Stefan W Ryter; Augustine M K Choi
Journal:  J Breath Res       Date:  2013-02-27       Impact factor: 3.262

3.  RES-Q-Trace: A Mobile CEAS-Based Demonstrator for Multi-Component Trace Gas Detection in the MIR.

Authors:  Norbert Lang; Uwe Macherius; Henrik Zimmermann; Sven Glitsch; Mathias Wiese; Jürgen Röpcke; Jean-Pierre H van Helden
Journal:  Sensors (Basel)       Date:  2018-06-27       Impact factor: 3.576

4.  Measurement of Exhaled Nitric Oxide in 456 Lung Cancer Patients Using a Ringdown FENO Analyzer.

Authors:  Jing Li; Qingyuan Li; Xin Wei; Qing Chen; Meixiu Sun; Yingxin Li
Journal:  Metabolites       Date:  2021-05-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.