Literature DB >> 20689946

Feasibility of 3-T MRI for the evaluation of Crohn disease in children.

Charuta Dagia1, Michael Ditchfield, Michael Kean, Anthony Catto-Smith.   

Abstract

BACKGROUND: Crohn disease (CD) is a chronic inflammatory bowel disease that can affect any part of the gastrointestinal tract from the oral cavity to the anal canal. It occurs in all ages and is a significant cause for morbidity in children. Interest in MRI evaluation of CD has increased because of the concern regarding cumulative radiation dose from contrast fluoroscopic studies and CT. Several reports have demonstrated MRI to be a useful technique for CD. Most of these studies were performed at 1.5-T field strength. Imaging at a higher field strength, with a greater signal-to-noise ratio, has the potential of reducing scan times and increasing the resolution. However, there is a concurrent increase in artefacts, and these can be pronounced with abdominal imaging at 3 T.
OBJECTIVE: To determine the feasibility of 3-T MRI for CD in children and to assess the value of different sequences and the effect of artefacts that could potentially limit the role of bowel MR imaging at higher field strengths.
MATERIALS AND METHODS: A retrospective study of 46 children with biopsy-proven CD (ages 8-19 years, 53% boys) was performed. Sixty-eight consecutive MRI studies were performed on a 3-T scanner between 2005 and 2007; 42 of the abdomen (62%) and 26 of the pelvis/perineum (38%). Sorbitol was administered for the abdominal studies; orally for 36/42 (86%) studies and via a naso-jejunal (NJ) tube for 6/42 (14%) studies. For the abdomen, T2-W half-fourier acquisition single-shot turbo spin-echo (T2-W HASTE), true steady-state free precession (true FISP), pre-contrast and contrast-enhanced (CE) T1-volume interpolated gradient-echo (T1-W VIBE) and CE T1-W fast low-angle shot (T1-W FLASH) sequences were performed. For the perianal and pelvic assessment, fat-saturated T2-W turbo spin-echo (TSE), pre-contrast and CE T1-W FLASH or VIBE sequences were performed. The sequences were scored for diagnostic quality by two paediatric radiologists for visualisation of the bowel wall, whether normal or pathological and the visualization of extra intestinal manifestations. The effects of distension, susceptibility artefact and motion were assessed.
RESULTS: Six (14%) abdominal MRI studies were normal. Thirty-six (86%) were abnormal with good correlation with endoscopic findings. The pelvic and perianal MRI studies were all abnormal (26/26, 100%) with good correlation with proctoscopy and examination under anaesthesia. All the sequences had high average scores (greater than or close to 3), except true FISP with a score of 2.4. The score was greatest in those who had NJ administration of sorbitol; however, satisfactory distension was also possible with oral administration of contrast. True FISP was the sequence most affected by a combination of suboptimal distension and artefact from colonic contents. With adequate distension, true FISP image quality improved remarkably. The overall score of this sequence was satisfactory in the absence of susceptibility and movement artefact.
CONCLUSION: With appropriate attention to technique, with optimal distension and control of movement, high-quality, 3-T assessment of the abdomen, pelvis and perineum is possible. All sequences used at 1.5 T can be used at 3 T, however true FISP was the most prone to artefact.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20689946     DOI: 10.1007/s00247-010-1781-9

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  22 in total

Review 1.  MRI of the small and large bowel.

Authors:  J F Debatin; M A Patak
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

Review 2.  Inflammatory bowel disease in early childhood and adolescence: special considerations.

Authors:  Petar Mamula; Jonathan E Markowitz; Robert N Baldassano
Journal:  Gastroenterol Clin North Am       Date:  2003-09       Impact factor: 3.806

Review 3.  CT and MRI of paediatric Crohn disease.

Authors:  Paolo Toma; Claudio Granata; Gianmichele Magnano; Arrigo Barabino
Journal:  Pediatr Radiol       Date:  2007-09-25

4.  Inflammatory bowel disease in children and adolescents: recommendations for diagnosis--the Porto criteria.

Authors: 
Journal:  J Pediatr Gastroenterol Nutr       Date:  2005-07       Impact factor: 2.839

5.  Polyethylene glycol and contrast-enhanced MRI of Crohn's disease in children: preliminary experience.

Authors:  Gianmichele Magnano; Claudio Granata; Arrigo Barabino; Francesca Magnaguagno; Umberto Rossi; Maria Grazia Calevo; Paolo Toma
Journal:  Pediatr Radiol       Date:  2003-04-05

6.  Feasibility of evaluating Crohn's disease activity at 3.0 Tesla.

Authors:  Karin van Gemert-Horsthuis; Jasper Florie; Daniel W Hommes; Cristina Lavini; Johannes B Reitsma; Sander J van Deventer; Jaap Stoker
Journal:  J Magn Reson Imaging       Date:  2006-08       Impact factor: 4.813

Review 7.  MRI in Crohn's disease.

Authors:  Karin Horsthuis; Cristina Lavini; Jaap Stoker
Journal:  J Magn Reson Imaging       Date:  2005-07       Impact factor: 4.813

Review 8.  Magnetic resonance imaging of the gastrointestinal tract.

Authors:  Diego R Martin; Raman Danrad; Karin Herrmann; Richard C Semelka; Shahid M Hussain
Journal:  Top Magn Reson Imaging       Date:  2005-02

9.  Diagnosis of fistulae and sinus tracts in patients with Crohn disease: value of MR imaging.

Authors:  G Koelbel; U Schmiedl; M C Majer; P Weber; H Jenss; K Kueper; C F Hess
Journal:  AJR Am J Roentgenol       Date:  1989-05       Impact factor: 3.959

10.  Imaging for Crohn disease: use of 3-T MRI in a paediatric setting.

Authors:  C Dagia; M Ditchfield; M Kean; T Catto-Smith
Journal:  J Med Imaging Radiat Oncol       Date:  2008-10       Impact factor: 1.735

View more
  7 in total

1.  Comparison between 1.5 and 3.0 Tesla magnetic resonance enterography for the assessment of disease activity and complications in ileo-colonic Crohn's disease.

Authors:  Gionata Fiorino; Cristiana Bonifacio; Mauro Padrenostro; Federica Mrakic Sposta; Antonino Spinelli; Alberto Malesci; Luca Balzarini; Laurent Peyrin-Biroulet; Silvio Danese
Journal:  Dig Dis Sci       Date:  2013-08-01       Impact factor: 3.199

Review 2.  Magnetic resonance imaging in children and adolescents with chronic inflammatory bowel disease.

Authors:  Hans-Joachim Mentzel; Steffen Reinsch; Monika Kurzai; Martin Stenzel
Journal:  World J Gastroenterol       Date:  2014-02-07       Impact factor: 5.742

Review 3.  Perianal disease in pediatric Crohn disease: a review of MRI findings.

Authors:  Gregory L Compton; Murray Bartlett
Journal:  Pediatr Radiol       Date:  2014-09-23

Review 4.  Imaging of the small bowel: Crohn's disease in paediatric patients.

Authors:  Emanuele Casciani; Chiara De Vincentiis; Elisabetta Polettini; Gabriele Masselli; Giovanni Di Nardo; Fortunata Civitelli; Salvatore Cucchiara; Gian Franco Gualdi
Journal:  World J Radiol       Date:  2014-06-28

5.  Features and perspectives of MR enterography for pediatric Crohn disease assessment.

Authors:  Noemi Maria Giovanna Ognibene; Massimo Basile; Marco Di Maurizio; Giuseppe Petrillo; Claudio De Filippi
Journal:  Radiol Med       Date:  2016-02-02       Impact factor: 3.469

Review 6.  MRI for Crohn's Disease: Present and Future.

Authors:  Kichul Yoon; Kyu-Tae Chang; Hong J Lee
Journal:  Biomed Res Int       Date:  2015-08-27       Impact factor: 3.411

7.  MR enterography in children: Principles, technique, and clinical applications.

Authors:  Govind B Chavhan; Paul S Babyn; Thomas Walters
Journal:  Indian J Radiol Imaging       Date:  2013-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.