Literature DB >> 20685519

Accuracy of surgical positioning of orthodontic miniscrews with a computer-aided design and manufacturing template.

Hong Liu1, Dong-xu Liu, Guangchun Wang, Chun-ling Wang, Zhen Zhao.   

Abstract

INTRODUCTION: Our objective was to enable accurate miniscrew placement after preoperative simulation. We developed a new template for miniscrew placement and evaluated its accuracy.
METHODS: Eleven patients who had bimaxillary protrusion were scanned with computed tomography. The 3-dimensional computed tomography data were used to produce, with stereolithography apparatus, a template for accurate miniscrew placement. The interradicular space available for miniscrew placement was calculated in the 3-dimensional images. Postoperative computed tomography images were matched with preoperative images to calculate the deviations between the planned and actual placements.
RESULTS: The distance for placement of a miniscrew between 2 roots was 4.12 mm (SD, 0.25 mm; range, 3.7-4.5 mm). The placed miniscrews showed an average angular deviation of 1.2 degrees (SD, 0.43 degrees ; range, 0.6 degrees -2.41 degrees ) compared with the plan, whereas the mean linear distomesial deviation was 0.42 mm (SD, 0.13 mm; range, 0.15-0.6 mm) at the tip.
CONCLUSIONS: The proposed template has high accuracy and will be especially useful for patients who require precise miniscrew placement. 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20685519     DOI: 10.1016/j.ajodo.2009.12.025

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  10 in total

1.  Three-dimensional evaluation of upper anterior alveolar bone dehiscence after incisor retraction and intrusion in adult patients with bimaxillary protrusion malocclusion.

Authors:  Qing-Yuan Guo; Shi-jie Zhang; Hong Liu; Chun-ling Wang; Fu-lan Wei; Tao Lv; Na-na Wang; Dong-xu Liu
Journal:  J Zhejiang Univ Sci B       Date:  2011-12       Impact factor: 3.066

2.  Accuracy of orthodontic miniscrew implantation guided by stereolithographic surgical stent based on cone-beam CT-derived 3D images.

Authors:  Lingling Qiu; Naoto Haruyama; Shoichi Suzuki; Daisuke Yamada; Naoto Obayashi; Toru Kurabayashi; Keiji Moriyama
Journal:  Angle Orthod       Date:  2011-08-17       Impact factor: 2.079

3.  Accuracy of a cone beam computed tomography-guided surgical stent for orthodontic mini-implant placement.

Authors:  Jae-Jung Yu; Gyu-Tae Kim; Yong-Suk Choi; Eui-Hwan Hwang; Janghyun Paek; Seong-Hun Kim; John C Huang
Journal:  Angle Orthod       Date:  2011-08-29       Impact factor: 2.079

4.  Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study.

Authors:  Li Su; Hui Song; Xiaofeng Huang
Journal:  BMC Oral Health       Date:  2022-06-24       Impact factor: 3.747

5.  Accuracy of Mini-Implant Placement Using a Computer-Aided Designed Surgical Guide, with Information of Intraoral Scan and the Use of a Cone-Beam CT.

Authors:  Georgios Vasoglou; Ioanna Stefanidaki; Konstantinos Apostolopoulos; Evmorfia Fotakidou; Michail Vasoglou
Journal:  Dent J (Basel)       Date:  2022-06-08

6.  Effect of large incisor retraction on upper airway morphology in adult bimaxillary protrusion patients.

Authors:  Yu Chen; Liu Hong; Chun-ling Wang; Shi-jie Zhang; Cong Cao; Fulan Wei; Tao Lv; Fan Zhang; Dong-xu Liu
Journal:  Angle Orthod       Date:  2012-03-30       Impact factor: 2.079

7.  Evaluation of orthodontic mini-implant placement: a CBCT study.

Authors:  Shilpa Kalra; Tulika Tripathi; Priyank Rai; Anup Kanase
Journal:  Prog Orthod       Date:  2014-11-18       Impact factor: 2.750

8.  Morphologic evaluation of root resorption after miniscrew assisted en mass retraction in adult bialveolar protrusion patients.

Authors:  Yu Chen; Dongxu Liu
Journal:  Head Face Med       Date:  2020-07-27       Impact factor: 2.151

9.  CBCT evaluation of the upper airway morphological changes in growing patients of class II division 1 malocclusion with mandibular retrusion using twin block appliance: a comparative research.

Authors:  Liang Li; Hong Liu; Huijuan Cheng; Yanzhao Han; Chunling Wang; Yu Chen; Jinlin Song; Dongxu Liu
Journal:  PLoS One       Date:  2014-04-04       Impact factor: 3.240

10.  Developing Customized Dental Miniscrew Surgical Template from Thermoplastic Polymer Material Using Image Superimposition, CAD System, and 3D Printing.

Authors:  Yu-Tzu Wang; Jian-Hong Yu; Lun-Jou Lo; Pin-Hsin Hsu; CHun-Li Lin
Journal:  Biomed Res Int       Date:  2017-02-09       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.