Landfill or digester gas can contain man-made volatile methylsiloxanes (VMS), usually in the range of a few milligrams per normal cubic metre (Nm(3)). Until now, no standard method for siloxane quantification exists and there is controversy with respect to which sampling procedure is most suitable. This paper presents an analytical and a sampling procedure for the quantification of common VMS in biogas via GC-MS and polyvinyl fluoride (Tedlar) bags. Two commercially available Tedlar bag models are studied. One is equipped with a polypropylene valve with integrated septum, the other with a dual port fitting made from stainless steel. Siloxane recovery in landfill gas samples is investigated as a function of storage time, temperature, surface-to-volume ratio and background gas. Recovery was found to depend on the type of fitting employed. The siloxanes sampled in the bag with the polypropylene valve show high and stable recovery, even after more than 30 days. Sufficiently low detection limits below 10 microg Nm(-3) and good reproducibility can be achieved. The method is therefore well applicable to biogas, greatly facilitating sampling in comparison with other common techniques involving siloxane enrichment using sorption media. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20685441     DOI: 10.1016/j.talanta.2010.04.001

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Phase ratio variation approach for the study of partitioning behavior of volatile organic compounds in polymer sample bags: Nalophan case study.

Authors:  Jim Van Durme; Bas Werbrouck
Journal:  Environ Sci Pollut Res Int       Date:  2015-03-21       Impact factor: 4.223

2.  Some insights into analytical bias involved in the application of grab sampling for volatile organic compounds: a case study against used Tedlar bags.

Authors:  Samik Ghosh; Ki-Hyun Kim; Jong Ryeul Sohn
Journal:  ScientificWorldJournal       Date:  2011-11-03

3.  Novel field-portable high-pressure adsorbent tube sampler prototype for the direct in situ preconcentration of trace compounds in gases at their working pressures: application to biomethane.

Authors:  Aurore Lecharlier; Hervé Carrier; Brice Bouyssiere; Guilhem Caumette; Pierre Chiquet; Isabelle Le Hécho
Journal:  RSC Adv       Date:  2022-03-30       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.