Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study.

M H Dave1, A Frotzler, N Spielmann, C Madjdpour, M Weiss.   

Abstract

BACKGROUND: This study compared the fluid leakage in the new 'tapered' shaped against the classic 'cylindrical' shaped tracheal tube cuffs when placed in different sized tracheas.
METHODS: The 7.5 mm internal diameter (ID) tracheal tube cuffs-Tapered Seal Guard (TSG), Standard Seal Guard (SSG), Hi-Lo, Microcuff, Ruesch, and Portex Profile-were compared in an in vitro apparatus. Vertical artificial tracheas with 16, 20, and 22 mm ID were intubated, 5 ml clear water was applied above the unlubricated tube cuffs, and fluid leakage was measured up to 60 min. Data of tapered vs non-tapered tube cuffs (16 observations) were compared for each tracheal diameter using the Mann-Whitney test.
RESULTS: Median (range) fluid leakage (ml) at 60 min was 2.14 (0.05-4.88), 1.14 (0.00-4.84), and 0.13 (0.00-1.32), respectively, for 16, 20, and 22 mm tracheas in the TSG tube studies when compared with 4.58 (0.44-4.88), 2.21 (0.00-4.81), and 0.00 (0.00-4.81) in the SSG tube and 4.54 (1.54-4.82), 0.90 (0.00-4.49), and 4.85 (4.40-4.99) in the Microcuff tube studies. Leakage in all polyvinylchloride (PVC) tube cuffs was almost complete (5 ml) within 5 min (P<0.001).
CONCLUSIONS: The tapered PU tube cuff was as effective as the cylindrical PU cuffs in smaller tracheal diameters and was more efficient than the cylindrical Microcuff PU tube cuff in larger tracheal diameter in preventing subglottic fluid leakage across the tube cuff tested in this in vitro study. PVC tube cuffs leaked much more and faster than PU cuffs.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20682571     DOI: 10.1093/bja/aeq202

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  26 in total

1.  Endotracheal tube cuff--small important part of a big issue.

Authors:  Shai Efrati; Israel Deutsch; Gabriel M Gurman
Journal:  J Clin Monit Comput       Date:  2012-01-03       Impact factor: 2.502

2.  Ventilator-associated pneumonia: update on etiology, prevention, and management.

Authors:  Oleksa Rewa; John Muscedere
Journal:  Curr Infect Dis Rep       Date:  2011-06       Impact factor: 3.725

Review 3.  Novel preventive strategies for ventilator-associated pneumonia.

Authors:  Andrea Coppadoro; Edward Bittner; Lorenzo Berra
Journal:  Crit Care       Date:  2012-12-12       Impact factor: 9.097

Review 4.  Technologic advances in endotracheal tubes for prevention of ventilator-associated pneumonia.

Authors:  Juan F Fernandez; Stephanie M Levine; Marcos I Restrepo
Journal:  Chest       Date:  2012-07       Impact factor: 9.410

5.  Impact of tapered-cuff tracheal tube on microaspiration of gastric contents in intubated critically ill patients: a multicenter cluster-randomized cross-over controlled trial.

Authors:  Emmanuelle Jaillette; Christophe Girault; Guillaume Brunin; Farid Zerimech; Hélène Behal; Arnaud Chiche; Céline Broucqsault-Dedrie; Cyril Fayolle; Franck Minacori; Isabelle Alves; Stéphanie Barrailler; Julien Labreuche; Laurent Robriquet; Fabienne Tamion; Emmanuel Delaporte; Damien Thellier; Claire Delcourte; Alain Duhamel; Saad Nseir
Journal:  Intensive Care Med       Date:  2017-03-16       Impact factor: 17.440

6.  Too passive to prevent ventilator-associated pneumonia.

Authors:  Juan Felipe Fernandez; Marcos I Restrepo
Journal:  Respir Care       Date:  2013-10       Impact factor: 2.258

7.  Orotracheal tube as a risk factor for lower respiratory tract infection: preliminary data from a randomised trial.

Authors:  Igor Muzlovic; Janja Perme; David Stubljar
Journal:  Wien Klin Wochenschr       Date:  2018-01-16       Impact factor: 1.704

8.  Pneumonia due to aspiration of povidine iodine after preoperative disinfection of the oral cavity.

Authors:  Takashi Hitosugi; Masanori Tsukamoto; Takeshi Yokoyama
Journal:  Oral Maxillofac Surg       Date:  2019-11-01

9.  A quantitative evaluation of fluid leakage around a polyvinyl chloride tapered endotracheal tube cuff using an in-vitro model.

Authors:  J Shiotsuka; A T Lefor; M Sanui; O Nagata; A Horiguchi; Y Sasabuchi
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2012

10.  The tracheal tube: gateway to ventilator-associated pneumonia.

Authors:  Parjam S Zolfaghari; Duncan L A Wyncoll
Journal:  Crit Care       Date:  2011-09-29       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.