Literature DB >> 20680061

Polarimetry-based method to extract geometry-independent metrics of tissue anisotropy.

Marika A Wallenburg1, Michael F G Wood, Nirmalya Ghosh, I Alex Vitkin.   

Abstract

Recently, we have used polarimetry as a method for assessing the linear retardance of infarcted myocardium. While linear retardance reflects tissue anisotropy, experimental geometry has a confounding effect due to dependence of the linear retardance on the orientation of the sample with respect to the probing beam. Here, polarimetry imaging of an 8mm diameter birefringent polystyrene sphere of known anisotropy axis was used to test a dual-projection method by which the anisotropy axis and its true magnitude can be reconstructed, thus eliminating the confounding effect of anisotropy axis orientation. Feasibility is demonstrated in ex-vivo tissue imaging.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20680061     DOI: 10.1364/OL.35.002570

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  7 in total

1.  Conical scan polarization-sensitive optical coherence tomography.

Authors:  Zenghai Lu; Deepa Kasaragod; Stephen J Matcher
Journal:  Biomed Opt Express       Date:  2014-02-18       Impact factor: 3.732

2.  Polarimetric study of birefringent turbid media with three-dimensional optic axis orientation.

Authors:  Noé Ortega-Quijano; Félix Fanjul-Vélez; José Luis Arce-Diego
Journal:  Biomed Opt Express       Date:  2013-12-19       Impact factor: 3.732

3.  Mapping 3D fiber orientation in tissue using dual-angle optical polarization tractography.

Authors:  Y Wang; M Ravanfar; K Zhang; D Duan; G Yao
Journal:  Biomed Opt Express       Date:  2016-09-01       Impact factor: 3.732

4.  A new approach for optical assessment of directional anisotropy in turbid media.

Authors:  Pejhman Ghassemi; Lauren T Moffatt; Jeffrey W Shupp; Jessica C Ramella-Roman
Journal:  J Biophotonics       Date:  2015-01-19       Impact factor: 3.207

5.  Assessment of local structural disorders of the bladder wall in partial bladder outlet obstruction using polarized light imaging.

Authors:  Sanaz Alali; Karen J Aitken; Annette Schröder; Adam Gribble; Darius J Bagli; I Alex Vitkin
Journal:  Biomed Opt Express       Date:  2014-01-27       Impact factor: 3.732

6.  as-PSOCT: Volumetric microscopic imaging of human brain architecture and connectivity.

Authors:  Hui Wang; Caroline Magnain; Ruopeng Wang; Jay Dubb; Ani Varjabedian; Lee S Tirrell; Allison Stevens; Jean C Augustinack; Ender Konukoglu; Iman Aganj; Matthew P Frosch; Jeremy D Schmahmann; Bruce Fischl; David A Boas
Journal:  Neuroimage       Date:  2017-10-07       Impact factor: 6.556

Review 7.  Optical phantoms for biomedical polarimetry: a review.

Authors:  Joseph Chue-Sang; Mariacarla Gonzalez; Angie Pierre; Megan Laughrey; Ilyas Saytashev; Tatiana Novikova; Jessica C Ramella-Roman
Journal:  J Biomed Opt       Date:  2019-03       Impact factor: 3.170

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.