Literature DB >> 20679699

Effect of transverse magnetic fields on a simulated in-line 6 MV linac.

J St Aubin1, S Steciw, B G Fallone.   

Abstract

The effects of a transverse magnetic field on an in-line side-coupled 6 MV linear accelerator are given. The results are directly applicable to a linac-MR system used for real-time image guided adaptive radiotherapy. Our previously designed end-to-end linac simulation incorporated the results from the axisymmetric 2D electron gun program EGN2w. However, since the magnetic fields being investigated are non-axisymmetric in nature for the work presented here, the electron gun simulation was performed using OPERA-3d/SCALA. The simulation results from OPERA-3d/SCALA showed excellent agreement with previous results. Upon the addition of external magnetic fields to our fully 3D linac simulation, it was found that a transverse magnetic field of 6 G resulted in a 45 +/- 1% beam loss, and by 14 G, no electrons were incident on the target. Transverse magnetic fields on the linac simulation produced a highly asymmetric focal spot at the target, which translated into a 13% profile asymmetry at 6 G. Upon translating the focal spot with respect to the target coordinates, profile symmetry was regained at the expense of a lateral shift in the dose profiles. It was found that all points in the penumbra failed a 1%/1 mm acceptance criterion for fields between 4 and 6 G. However, it was also found that the lateral profile shifts were corrected by adjusting the jaw positions asymmetrically.

Mesh:

Year:  2010        PMID: 20679699     DOI: 10.1088/0031-9155/55/16/015

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators.

Authors:  Dragoş E Constantin; Rebecca Fahrig; Paul J Keall
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

2.  Performance of a clinical gridded electron gun in magnetic fields: Implications for MRI-linac therapy.

Authors:  Brendan Whelan; Lois Holloway; Dragos Constantin; Brad Oborn; Magdalena Bazalova-Carter; Rebecca Fahrig; Paul Keall
Journal:  Med Phys       Date:  2016-11       Impact factor: 4.071

3.  A novel electron accelerator for MRI-Linac radiotherapy.

Authors:  Brendan Whelan; Stephen Gierman; Lois Holloway; John Schmerge; Paul Keall; Rebecca Fahrig
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

4.  Dosimetric feasibility of real-time MRI-guided proton therapy.

Authors:  M Moteabbed; J Schuemann; H Paganetti
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

5.  MR-guidance--a clinical study to evaluate a shuttle- based MR-linac connection to provide MR-guided radiotherapy.

Authors:  Tilman Bostel; Nils H Nicolay; Jörg G Grossmann; Angela Mohr; Stefan Delorme; Gernot Echner; Peter Häring; Jürgen Debus; Florian Sterzing
Journal:  Radiat Oncol       Date:  2014-01-09       Impact factor: 3.481

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.