Proton range verification using a range probe: definition of concept and initial analysis.

M Mumot1, C Algranati, M Hartmann, J M Schippers, E Hug, A J Lomax.   

Abstract

Proton therapy can be particularly sensitive to changes or errors in range. Thus, methods for the in vivo measurement of range could be of great use to improve the quality and accuracy of proton-based radiotherapy. In this paper, we introduce the concept of the 'range probe'. This is a low-dose, high-energy proton pencil beam that would pass through a patient, and whose integral Bragg peak would be measured on the exit side using a multi-layer detector. We propose that by comparing the measured integral Bragg peak with that calculated based on the patient's planning CT, such a range probe could provide useful information about the accuracy of range calculations in vivo. To study the feasibility of this approach, a Monte Carlo-based study has been performed. Using a patient's planning CT, MC simulations (VMCpro) have been made for single pencil beams laterally traversing the head and stopping in a simulated range telescope behind the patient. Range probes have been calculated for different locations, and the residual range from the Bragg peak 'signal' in the range telescope has been assessed for different assumed detector thicknesses. The sensitivity of this approach to changes in CT values, calibration curve and positional shifts of the CT have been investigated. From our analysis, range resolutions of 1 mm may be possible with a detector thickness of 4 mm for homogeneous regions. Additionally, for heterogeneous regions, changes of the Bragg peak shape due to spatial shifts of the CT could be a sensitive measure for detecting patient set-up errors directly in the treatment position. The concept of the proton 'range probe' appears to be feasible for high-resolution range verification. We now want to test this concept experimentally using different possible range telescope detectors.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20679697     DOI: 10.1088/0031-9155/55/16/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Wax boluses and accuracy of EBT and RTQA radiochromic film detectors in radiotherapy with the JINR Phasotron proton beam.

Authors:  Dorota Maria Borowicz; Julian Malicki; Gennady Mytsin; Konstantin Shipulin
Journal:  Rep Pract Oncol Radiother       Date:  2013-07-02

Review 2.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

Review 3.  Online daily adaptive proton therapy.

Authors:  Francesca Albertini; Michael Matter; Lena Nenoff; Ye Zhang; Antony Lomax
Journal:  Br J Radiol       Date:  2019-11-11       Impact factor: 3.039

4.  Proton radiography and fluoroscopy of lung tumors: a Monte Carlo study using patient-specific 4DCT phantoms.

Authors:  Bin Han; X George Xu; George T Y Chen
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

Review 5.  Charged particle therapy--optimization, challenges and future directions.

Authors:  Jay S Loeffler; Marco Durante
Journal:  Nat Rev Clin Oncol       Date:  2013-05-21       Impact factor: 66.675

6.  Mid-range probing-towards range-guided particle therapy.

Authors:  Mingli Chen; Yuncheng Zhong; Yiping Shao; Steve Jiang; Weiguo Lu
Journal:  Phys Med Biol       Date:  2018-06-27       Impact factor: 3.609

7.  Analysis of characteristics of images acquired with a prototype clinical proton radiography system.

Authors:  Christina Sarosiek; Ethan A DeJongh; George Coutrakon; Don F DeJongh; Kirk L Duffin; Nicholas T Karonis; Caesar E Ordoñez; Mark Pankuch; Victor Rykalin; John R Winans; James S Welsh
Journal:  Med Phys       Date:  2021-03-22       Impact factor: 4.071

8.  Improved beam angle arrangement in intensity modulated proton therapy treatment planning for localized prostate cancer.

Authors:  Wenhua Cao; Gino J Lim; Yupeng Li; X Ronald Zhu; Xiaodong Zhang
Journal:  Cancers (Basel)       Date:  2015-03-30       Impact factor: 6.639

9.  Evaluation of detectors for acquisition of pristine depth-dose curves in pencil beam scanning.

Authors:  Christian Bäumer; Benjamin Koska; Jamil Lambert; Beate Timmermann; Thierry Mertens; Patrick Takoukam Talla
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

10.  Quantitative assessment of anatomical change using a virtual proton depth radiograph for adaptive head and neck proton therapy.

Authors:  Peng Wang; Lingshu Yin; Yawei Zhang; Maura Kirk; Gang Song; Peter H Ahn; Alexander Lin; James Gee; Derek Dolney; Timothy D Solberg; Richard Maughan; James McDonough; Boon-Keng Kevin Teo
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.