Literature DB >> 20679004

3-D in vitro estimation of temperature using the change in backscattered ultrasonic energy.

R Martin Arthur1, Debomita Basu, Yuzheng Guo, Jason W Trobaugh, Eduardo G Moros.   

Abstract

Temperature imaging with a non-invasive modality to monitor the heating of tumors during hyperthermia treatment is an attractive alternative to sparse invasive measurement. Previously, we predicted monotonic changes in backscattered energy (CBE) of ultrasound with temperature for certain sub-wavelength scatterers. We also measured CBE values similar to our predictions in bovine liver, turkey breast muscle, and pork rib muscle in 2-D in vitro studies and in nude mice during 2-D in vivo studies. To extend these studies to three dimensions, we compensated for motion and measured CBE in turkey breast muscle. 3-D data sets were assembled from images formed by a phased-array imager with a 7.5-MHz linear probe moved in 0.6-mm steps in elevation during uniform heating from 37 to 45 degrees C in 0.5 degrees C increments. We used cross-correlation as a similarity measure in RF signals to automatically track feature displacement as a function of temperature. Feature displacement was non-rigid. Envelopes of image regions, compensated for non-rigid motion, were found with the Hilbert transform then smoothed with a 3 x 3 running average filter before forming the backscattered energy at each pixel. CBE in 3-D motion-compensated images was nearly linear with an average sensitivity of 0.30 dB/ degrees C. 3-D estimation of temperature in separate tissue regions had errors with a maximum standard deviation of about 0.5 degrees C over 1-cm(3) volumes. Success of CBE temperature estimation based on 3-D non-rigid tracking and compensation for real and apparent motion of image features could serve as the foundation for the eventual generation of 3-D temperature maps in soft tissue in a non-invasive, convenient, and low-cost way in clinical hyperthermia.

Entities:  

Mesh:

Year:  2010        PMID: 20679004     DOI: 10.1109/TUFFC.2010.1611

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  12 in total

1.  Dual-wavelength photoacoustic technique for monitoring tissue status during thermal treatments.

Authors:  Yi-Sing Hsiao; Xueding Wang; Cheri X Deng
Journal:  J Biomed Opt       Date:  2013-06       Impact factor: 3.170

Review 2.  Imaging-based internal body temperature measurements: The journal Temperature toolbox.

Authors:  Juho Raiko; Kalle Koskensalo; Teija Sainio
Journal:  Temperature (Austin)       Date:  2020-05-29

3.  Thermal strain imaging: a review.

Authors:  Chi Hyung Seo; Yan Shi; Sheng-Wen Huang; Kang Kim; Matthew O'Donnell
Journal:  Interface Focus       Date:  2011-05-23       Impact factor: 3.906

4.  Exploring potential mechanisms responsible for observed changes of ultrasonic backscattered energy with temperature variations.

Authors:  Xin Li; Goutam Ghoshal; Roberto J Lavarello; Michael L Oelze
Journal:  Med Phys       Date:  2014-05       Impact factor: 4.071

Review 5.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

6.  High-frequency ultrasound m-mode imaging for identifying lesion and bubble activity during high-intensity focused ultrasound ablation.

Authors:  Ronald E Kumon; Madhu S R Gudur; Yun Zhou; Cheri X Deng
Journal:  Ultrasound Med Biol       Date:  2012-02-15       Impact factor: 2.998

7.  Real-time Ultrasound Thermography and Thermometry.

Authors:  Emad S Ebbini; Claudio Simon; Dalong Liu
Journal:  IEEE Signal Process Mag       Date:  2018-03-09       Impact factor: 12.551

8.  Characterization of Lesion Formation and Bubble Activities during High Intensity Focused Ultrasound Ablation using Temperature-Derived Parameters.

Authors:  Yi-Sing Hsiao; Ronald E Kumon; Cheri X Deng
Journal:  Infrared Phys Technol       Date:  2013-09-01       Impact factor: 2.638

9.  Feasibility of A-mode ultrasound attenuation as a monitoring method of local hyperthermia treatment.

Authors:  Noraida Abd Manaf; Maizatul Nadwa Che Aziz; Dzulfadhli Saffuan Ridzuan; Maheza Irna Mohamad Salim; Asnida Abd Wahab; Khin Wee Lai; Yan Chai Hum
Journal:  Med Biol Eng Comput       Date:  2016-04-02       Impact factor: 2.602

10.  Calibration and Evaluation of Ultrasound Thermography Using Infrared Imaging.

Authors:  Yi-Sing Hsiao; Cheri X Deng
Journal:  Ultrasound Med Biol       Date:  2015-11-05       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.