Literature DB >> 20678997

The patellar tendon bar! Is it a necessary feature?

N A Abu Osman1, W D Spence, S E Solomonidis, J P Paul, A M Weir.   

Abstract

The purpose of this investigation was to vary the load on the patellar tendon bar and to study the subsequent effect this has on the pattern of the pressure distribution at the stump-socket interface. Ten male subjects from the Southern General Hospital in Glasgow, UK participated in this study. Measuring systems utilising strain gauge and electrohydraulic technologies were designed, developed and constructed to enable pressure measurements to be conducted. One transducer, the patellar tendon (PT) transducer, was attached to the patellar tendon bar of the socket such that the patellar tendon bar was capable of being translated by +/-10 mm towards or away from the tendon. The results of this study showed that the position of the patellar tendon bar had no significant effect on the pressure distribution around the socket indicating that it is an unnecessary feature, which, we propose, may be eliminated during manufacture of a trans-tibial socket. 2010 IPEM. All rights reserved.

Mesh:

Year:  2010        PMID: 20678997     DOI: 10.1016/j.medengphy.2010.04.020

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Textile-based Pressure Sensors for Monitoring Prosthetic-Socket Interfaces.

Authors:  Jordan Tabor; Talha Agcayazi; Aaron Fleming; Brendan Thompson; Ashish Kapoor; Ming Liu; Michael Lee; He Helen Huang; Alper Bozkurt; Tushar Ghosh
Journal:  IEEE Sens J       Date:  2021-01-21       Impact factor: 3.301

2.  Clinical implication of interface pressure for a new prosthetic suspension system.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Nasrul Anuar Abd Razak
Journal:  Biomed Eng Online       Date:  2014-06-30       Impact factor: 2.819

Review 3.  The use of fiber Bragg grating sensors in biomechanics and rehabilitation applications: the state-of-the-art and ongoing research topics.

Authors:  Ebrahim Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahamd Adikan
Journal:  Sensors (Basel)       Date:  2012-09-25       Impact factor: 3.576

4.  The capability of fiber Bragg grating sensors to measure amputees' trans-tibial stump/socket interface pressures.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Arezoo Eshraghi; Faisal Rafiq Mahamd Adikan
Journal:  Sensors (Basel)       Date:  2013-08-12       Impact factor: 3.576

Review 5.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.