Literature DB >> 20678464

Voltammetric determination of cefixime in pharmaceuticals and biological fluids.

Rajeev Jain1, Vinod K Gupta, N Jadon, K Radhapyari.   

Abstract

Electroreduction and adsorption of cefixime was studied in phosphate buffer by cyclic voltammetry (CV), differential pulse cathodic adsorptive stripping voltammetry (DPCAdSV), and square-wave cathodic adsorptive stripping voltammetry (SWCAdSV) at hanging mercury drop electrode (HMDE). These fully validated sensitive and reproducible cathodic adsorptive stripping voltammetric procedures were applied for the trace determination of the bulk drug in pharmaceutical formulations and in human urine. The optimal experimental parameters were as follows: accumulation potential=-0.1 V (vs. Ag/AgCl, 3M KCl), accumulation time=50s, frequency=140 Hz, pulse amplitude=0.07 V, and scan increment=10 mV in phosphate buffer (pH 2.6). The first peak current showed a linear dependence with the drug concentration over the range of 50 ng ml(-1) to 25.6 μg ml(-1). The achieved limit of detection and limit of quantitation were 3.99 and 13.3 ng ml(-1) by SWCAdSV and 7.98 and 26.6 ng ml(-1) by DPCAdSV, respectively. The procedure was applied to assay the drug in tablets. Applicability was also tested in urine samples. Peak current was linear with the drug concentration in the range of 1 to 60 μg ml(-1) of the urine, and minimum detectability was found to be 12.6 ng ml(-1) by SWCAdSV and 58.4 ng ml(-1) by DPCAdSV.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20678464     DOI: 10.1016/j.ab.2010.07.027

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  18 in total

1.  Fabrication of novel TiO2 nanoparticles/Mn(III) salen doped carbon paste electrode: application as electrochemical sensor for the determination of hydrazine in the presence of phenol.

Authors:  Hadi Mahmoudi Moghaddam; Hadi Beitollahi; Somayeh Tajik; Iran Sheikhshoaie; Pourya Biparva
Journal:  Environ Monit Assess       Date:  2015-06-05       Impact factor: 2.513

2.  Construction of a nanostructure-based electrochemical sensor for voltammetric determination of bisphenol A.

Authors:  Hadi Beitollahi; Somayeh Tajik
Journal:  Environ Monit Assess       Date:  2015-04-16       Impact factor: 2.513

3.  Electrochemical determination of hydrazine using a ZrO2 nanoparticles-modified carbon paste electrode.

Authors:  Sayed Zia Mohammadi; Hadi Beitollahi; Elina Bani Asadi
Journal:  Environ Monit Assess       Date:  2015-02-19       Impact factor: 2.513

4.  Fluorescent Carbon Dot as Nanosensor for Sensitive and Selective Detection of Cefixime Based on Inner Filter Effect.

Authors:  Farhad Akhgari; Naser Samadi; Khalil Farhadi
Journal:  J Fluoresc       Date:  2017-01-11       Impact factor: 2.217

Review 5.  Carbon-based Nanomaterials and Curcumin: A Review of Biosensing Applications.

Authors:  Mohammad Mohajeri; Behzad Behnam; Aida Tasbandi; Tannaz Jamialahmadi; Amirhossein Sahebkar
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

6.  Schiff Base Derived from 4,4'-methylenedianiline and p-anisaldehyde: Colorimetric Sensor for Cu2+, Paper Strip Sensor for Al3+ and Fluorescent Sensor for Pb2.

Authors:  Diganta Kumar Das; Satyapriya Deka; Ankur Kanti Guha
Journal:  J Fluoresc       Date:  2019-11-30       Impact factor: 2.217

7.  Determination of Cefixime by a Validated Stability-Indicating HPLC Method and Identification of its Related Substances by LC-MS/MS Studies.

Authors:  Zahra Talebpour; Hakimeh Pourabdollahi; Hasan Rafati; Asem Abdollahpour; Yusef Bashour; Hassan Y Aboul-Enein
Journal:  Sci Pharm       Date:  2013-02-18

8.  Spectrophotometric Determination of Cefixime Trihydrate in Pharmaceutical Formulations Based on Ion-Pair Reaction with Bromophenol Blue.

Authors:  Mrudul R Keskar; Ravin M Jugade
Journal:  Anal Chem Insights       Date:  2015-07-27

Review 9.  Preparation of magnetic carbon nanotubes (Mag-CNTs) for biomedical and biotechnological applications.

Authors:  Andrea Masotti; Andrea Caporali
Journal:  Int J Mol Sci       Date:  2013-12-18       Impact factor: 5.923

10.  Spectrofluorimetric determination of cefixime using terbium-danofloxacin probe.

Authors:  Jamshid L Manzoori; Mohammad Amjadi; Naser Soltani; Abolghasem Jouyban
Journal:  Iran J Basic Med Sci       Date:  2014       Impact factor: 2.699

View more